UPS battery backup · US 120V

APC BE850G2

A full desk of equipment: a computer, its monitors and the network gear that has to stay up with it.

Capacity
850 VA
Real power limit
450 W
On battery
Stepped approximation to a sinewave
Design
Standby
Check current price on eBay ↗

Estimated price: about $80 Our estimate for a new unit, from listings seen in November 2026. Not a live price.

APC BE850G2 uninterruptible power supply (UPS) Standby (Offline) 0.85 kVA 450 W 9 AC outlet(s) uninterruptible power supply
MPN BE850G2

Compare new-unit eBay listings

This model has no qualifying listing at the moment. A listing appears here as soon as one does.

We may earn a commission if you buy through these links.

No new unit of this model is listed at a checked price right now. Used and pickup-only listings exist on eBay and are deliberately not shown: every price on this site is a new unit that ships, so a used one has no comparable figure to put beside it. The specifications below are unaffected — they describe the model, not a listing.

What this model actually powers

A limit this size carries a complete desk — desktop, monitors, network — or a living-room setup, with room left over for the storage box beside it.

Each example adds up published power figures for real equipment and compares the total with this model’s 450 W real-power limit as published by the manufacturer. The examples shown are the ones nearest this limit; a bundle far below or far above it would say nothing useful. These are running-load figures, not startup surge, and your own equipment will differ.

  • Creator workstation, two monitors and a 4-bay NAS

    86.2–231.2 W19–51% of this model’s 450 W

    about 218.8 W free

    Room for one more Mac mini (M4 Pro) idle-to-max (140 W), but not a Mac Studio (M3 Ultra) idle-to-max (270 W).

    What is in this example
    • Mac Studio (M4 Max) idle-to-max power: 6–145 W (source)
    • 32-inch monitor operating power: 27.8 W (source)
    • 27-inch monitor typical and rated power: 20–26 W (source)
    • 4-bay NAS access power: 32.41 W (source)
  • TV, console and soundbar

    247.2–283.2 W55–63% of this model’s 450 W

    about 166.8 W free

    Room for one more Mac Studio (M4 Max) idle-to-max (145 W), but not a Mac Studio (M3 Ultra) idle-to-max (270 W).

    What is in a TV, console and soundbar, and every model measured against it

  • Home server closet

    131.1–294.5 W29–65% of this model’s 450 W

    about 155.5 W free

    Room for one more Mac Studio (M4 Max) idle-to-max (145 W), but not a Mac Studio (M3 Ultra) idle-to-max (270 W).

    What is in this example
    • 8-bay NAS sleep-to-typical power: 25.668–54.067 W (source)
    • 8-port PoE+ switch maximum power: 90 W (source)
    • Mac mini (M4 Pro) idle-to-max power: 5–140 W (source)
    • Wi-Fi router active power: 5.2 W (source)
    • Cable modem active power: 5.2 W (source)
  • High-end workstation with an 8-bay NAS

    82.5–377.9 W18–84% of this model’s 450 W

    about 72.1 W free

    Room for one more Mac mini (M4) idle-to-max (65 W), but not a soundbar system component (75 W).

    What is in this example
    • Mac Studio (M3 Ultra) idle-to-max power: 9–270 W (source)
    • 32-inch monitor operating power: 27.8 W (source)
    • 27-inch monitor typical and rated power: 20–26 W (source)
    • 8-bay NAS sleep-to-typical power: 25.668–54.067 W (source)
  • Two workstations sharing a NAS

    112.2–525.2 W25–117% of this model’s 450 W

    more than this model can carry

    What is in this example
    • Mac Studio (M3 Ultra) idle-to-max power: 9–270 W (source)
    • Mac Studio (M4 Max) idle-to-max power: 6–145 W (source)
    • 32-inch monitor operating power: 27.8 W (source)
    • 27-inch monitor typical and rated power: 20–26 W (source)
    • 24-inch monitor typical and rated power: 17–24 W (source)
    • 4-bay NAS access power: 32.41 W (source)

A UPS runs longer the less it carries, so a total near the limit buys less time than a light one. Startup draw is not included because it depends on the equipment you connect.

BE850G2 published runtime

Manufacturer reference points, not a runtime guarantee for your setup. Battery age, temperature and equipment load affect results.

11.4 min50% of rated load
2.4 min100% of rated load

Where these runtime figures come from

Check your equipment load

Start with the watts you know. Add VA from your equipment or meter when available. Each result checks one limit; startup demand and waveform compatibility need separate confirmation.

The W and VA limits used here come from the manufacturer specification.

This model has 6 manufacturer-verified battery-backed outlets. Count plugs connected directly to the UPS. Surge-only outlets do not keep equipment running during an outage. Check adapter spacing in the outlet diagram. View sources

Which outlets stay live

  • 6 outlets on battery of 9; the other 3 outlets are surge-only and go dark with the mains. Among the 14 of 15 models tracked here that publish this figure, values run from 4 to 10 with a midpoint of 6.5. This model's 6 is below that midpoint.
  • Socket type: 6 NEMA 5-15R, 3 NEMA 5-15R surge — household plugs fit directly. Plug families

How long each example would run

From the manufacturer’s runtime curve at half load (11.4 min) and at full load (2.4 min). The curve is the manufacturer’s estimate for new, fully charged batteries, and reads somewhat above the figures datasheets print where both exist. Bounds only.

  • Creator workstation, two monitors and a 4-bay NAS at 51% of the limit: between 2.4 and 11.4 min.
  • TV, console and soundbar at 63% of the limit: between 2.4 and 11.4 min.
  • Home server closet at 65% of the limit: between 2.4 and 11.4 min.
  • High-end workstation with an 8-bay NAS at 84% of the limit: between 2.4 and 11.4 min.

How it switches to battery

  • Standby — the inverter starts only on failure; an active-PFC supply may reset on the gap. How this design behaves
  • Transfer time: 6 ms — inside most supplies’ hold-up time, with less margin under heavy load. Among the 11 of 15 models tracked here that publish this figure, values run from 2 ms to 6 ms with a midpoint of 6 ms. This model's 6 ms sits at the high end: none of the models tracked here publishes a higher figure. Hold-up time

Running it from a generator

  • Accepts 57–63 Hz (6 Hz wide) — narrow: a generator whose frequency drifts will push it onto battery repeatedly. What transferring means

Noise, temperature and certifications

  • 45 dB — a fan you will hear; closet or rack, not a desk. Among the 14 of 15 models tracked here that publish this figure, values run from 40 dB to 55 dB with a midpoint of 45 dB. This model's 45 dB is within 2% of that midpoint, which is too close to call a difference. Reading noise figures
  • Operating temperature 0 - 40 °C. Batteries age fastest at the top of that range.
  • Certifications: California (CEC) Battery Charger, CSA C22.2 NO. 107.3, cTUVus, FCC Part 15 Class B, UL 1778.

What changes in the same capacity range

Compare the published limits before paying for more capacity. A higher power rating alone does not establish longer runtime.

APC SMTL750RM2UC uninterruptible power supply (UPS) Line-Interactive 0.75 kVA 600 W 6 AC outlet(s)
  • VA: 750 VA vs 850 VA
  • Watts: 600 W vs 450 W
  • On Battery Waveform: Sine wave vs Stepped approximation to a sinewave
  • UPS Topology: Line Interactive vs Standby
APC SMX750C uninterruptible power supply (UPS) Line-Interactive 0.75 kVA 675 W 8 AC outlet(s)
  • VA: 750 VA vs 850 VA
  • Watts: 675 W vs 450 W
  • On Battery Waveform: Sine wave vs Stepped approximation to a sinewave
  • UPS Topology: Line Interactive vs Standby

Where this model appears next to others

Same figures as above, arranged against a different question.

Full specifications

46 published figures, grouped. The largest groups are open; the rest expand. Each group names where its figures came from.

Power9 figures
VA
850 VA
Watts
450 W
On Battery Waveform
Stepped approximation to a sinewave
UPS Topology
Standby
Typical Transfer Time
6 ms
Input Plug Type
NEMA 5-15P
Nominal Input Voltage
120 V
Surge Suppression (Joules)
354 J
Input Frequency Range
57–63 Hz

APC specification ↗

Battery7 figures
Typical Recharge Time
8 h
Replacement Battery Cartridge
RBC17
Runtime at Half Load
11.4 min
Runtime at Full Load
2.4 min
Battery capacity
104 Ah
Battery life max
5 year(s)
Battery technology
Sealed Lead Acid (VRLA)

APC specification, APC runtime curve (estimate), icecat ↗ — manufacturer-checked and catalogue values, see Sources

Features6 figures
Highest input voltage it runs on
139 V
Lowest input voltage it runs on
92 V
Output operation voltage max
120 V
Output operation voltage min
120 V
Response time
6 ms
Surge protection
Y

icecat — catalogue values, not manufacturer-checked

Operational conditions6 figures
Non operating altitude
0 - 15000 m
Operating altitude
0 - 3000 m
Operating relative humidity range
0 - 95 %
Operating temperature range
0 - 40 °C
Storage relative humidity range
10 - 90 %
Storage temperature range
-15 - 45 °C

icecat — catalogue values, not manufacturer-checked

Outlets4 figures
Outlet Type
6 NEMA 5-15R, 3 NEMA 5-15R surge
Outlets – Total
9
Outlets – Surge-Only Protected
3
Outlets – Battery & Surge Protected
6

APC specification ↗

Packaging data4 figures
Package depth
168 mm
Package height
196 mm
Package weight
4400 g
Package width
416 mm

icecat — catalogue values, not manufacturer-checked

Weight & dimensions3 figures
Depth
105 mm
Height
139 mm
Width
327 mm

icecat — catalogue values, not manufacturer-checked

Physical2 figures
Physical Weight (lb)
9.04 lb
Cord Length
1.5 m

APC specification ↗

Ports & interfaces2 figures
USB 2.0 ports
2
USB port
Y

icecat — catalogue values, not manufacturer-checked

Environment1 figure
Audible Noise
45 dB

APC specification ↗

Certificates1 figure
Certification
California (CEC) Battery Charger, CSA C22.2 NO. 107.3, cTUVus, FCC Part 15 Class B, UL 1778

icecat — catalogue values, not manufacturer-checked

Design1 figure
Product colour
Black

icecat — catalogue values, not manufacturer-checked

Sources and buying notes

This comparison uses published specifications, not hands-on tests. Prices are listing observations and can change. Read our full methodology.

Before you order

  • Startup demand: Startup draw depends on the connected equipment.
  • Equipment compatibility: Confirm plug, voltage, waveform, and both W and VA limits.

Comparison updated October 19, 2026.