UPS battery backup · US 120V

APC BE900G3

A full desk of equipment: a computer, its monitors and the network gear that has to stay up with it.

Capacity
900 VA
Real power limit
540 W
On battery
Stepped approximation to a sinewave
Design
Standby
Check current price on eBay ↗

Estimated price: about $210 Our estimate for a new unit, from listings seen in November 2026. Not a live price.

APC BE900G3 uninterruptible power supply (UPS) Standby (Offline) 0.9 kVA 540 W 8 AC outlet(s) uninterruptible power supply
MPN BE900G3

What to know before buying

No published runtime figures for this model

No source we accept states how many minutes this unit runs at any load, so this page cannot compare it with an outage or say how long any example would last. Size it by watts, treat the battery as time to shut down cleanly, and check the manufacturer's runtime chart before relying on it for more.

Compare new-unit eBay listings

This model has no qualifying listing at the moment. A listing appears here as soon as one does.

We may earn a commission if you buy through these links.

No new unit of this model is listed at a checked price right now. Used and pickup-only listings exist on eBay and are deliberately not shown: every price on this site is a new unit that ships, so a used one has no comparable figure to put beside it. The specifications below are unaffected — they describe the model, not a listing.

What this model actually powers

A limit this size carries a complete desk — desktop, monitors, network — or a living-room setup, with room left over for the storage box beside it.

Each example adds up published power figures for real equipment and compares the total with this model’s 540 W real-power limit as published by the manufacturer. The examples shown are the ones nearest this limit; a bundle far below or far above it would say nothing useful. These are running-load figures, not startup surge, and your own equipment will differ.

  • TV, console and soundbar

    247.2–283.2 W46–52% of this model’s 540 W

    about 256.8 W free

    Room for one more Mac Studio (M4 Max) idle-to-max (145 W), but not a Mac Studio (M3 Ultra) idle-to-max (270 W).

    What is in a TV, console and soundbar, and every model measured against it

  • Home server closet

    131.1–294.5 W24–55% of this model’s 540 W

    about 245.5 W free

    Room for one more Mac Studio (M4 Max) idle-to-max (145 W), but not a Mac Studio (M3 Ultra) idle-to-max (270 W).

    What is in this example
    • 8-bay NAS sleep-to-typical power: 25.668–54.067 W (source)
    • 8-port PoE+ switch maximum power: 90 W (source)
    • Mac mini (M4 Pro) idle-to-max power: 5–140 W (source)
    • Wi-Fi router active power: 5.2 W (source)
    • Cable modem active power: 5.2 W (source)
  • High-end workstation with an 8-bay NAS

    82.5–377.9 W15–70% of this model’s 540 W

    about 162.1 W free

    Room for one more Mac Studio (M4 Max) idle-to-max (145 W).

    What is in this example
    • Mac Studio (M3 Ultra) idle-to-max power: 9–270 W (source)
    • 32-inch monitor operating power: 27.8 W (source)
    • 27-inch monitor typical and rated power: 20–26 W (source)
    • 8-bay NAS sleep-to-typical power: 25.668–54.067 W (source)
  • Two workstations sharing a NAS

    112.2–525.2 W21–97% of this model’s 540 W

    about 14.8 W free

    Room for one more Raspberry Pi 5 peak observed (12 W), but not a 2-bay NAS (15 W).

    What is in this example
    • Mac Studio (M3 Ultra) idle-to-max power: 9–270 W (source)
    • Mac Studio (M4 Max) idle-to-max power: 6–145 W (source)
    • 32-inch monitor operating power: 27.8 W (source)
    • 27-inch monitor typical and rated power: 20–26 W (source)
    • 24-inch monitor typical and rated power: 17–24 W (source)
    • 4-bay NAS access power: 32.41 W (source)
  • Small studio: two desks, storage and network

    182.7–613.1 W34–114% of this model’s 540 W

    more than this model can carry

    What is in this example
    • Mac Studio (M3 Ultra) idle-to-max power: 9–270 W (source)
    • Mac mini (M4 Pro) idle-to-max power: 5–140 W (source)
    • 32-inch monitor operating power: 27.8 W (source)
    • 27-inch monitor typical and rated power: 20–26 W (source)
    • 8-bay NAS sleep-to-typical power: 25.668–54.067 W (source)
    • 8-port PoE+ switch maximum power: 90 W (source)
    • Wi-Fi router active power: 5.2 W (source)

A UPS runs longer the less it carries, so a total near the limit buys less time than a light one. Startup draw is not included because it depends on the equipment you connect.

Check your equipment load

Start with the watts you know. Add VA from your equipment or meter when available. Each result checks one limit; startup demand and waveform compatibility need separate confirmation.

The W and VA limits used here come from the manufacturer specification.

This model has 6 manufacturer-verified battery-backed outlets. Count plugs connected directly to the UPS. Surge-only outlets do not keep equipment running during an outage. Check adapter spacing in the outlet diagram. View sources

Which outlets stay live

  • 6 outlets on battery of 8; the other 2 outlets are surge-only and go dark with the mains. Among the 9 of 15 models tracked here that publish this figure, values run from 4 to 10 with a midpoint of 5. This model's 6 is above that midpoint.
  • Socket type: 6 NEMA 5-15R, 2 NEMA 5-15R surge — household plugs fit directly. Plug families

How it switches to battery

  • Standby — the inverter starts only on failure; an active-PFC supply may reset on the gap. How this design behaves
  • Transfer time: 6 ms — inside most supplies’ hold-up time, with less margin under heavy load. Among the 14 of 15 models tracked here that publish this figure, values run from 2 ms to 10 ms with a midpoint of 6 ms. This model's 6 ms is within 2% of that midpoint, which is too close to call a difference. Hold-up time

The battery and what replacing it involves

  • Lead-acid (sealed lead-acid — fades over three to five years regardless of use). Why chemistry sets the interval
  • Recharge: about 8 h to full. Among the 14 of 15 models tracked here that publish this figure, values run from 3 h to 16 h with a midpoint of 8 h. This model's 8 h is within 2% of that midpoint, which is too close to call a difference.
  • Rated life: up to 5 years — the replacement interval to budget for. Among the 5 of 15 models tracked here that publish this figure, values run from 5 years to 6 years with a midpoint of 5 years. This model's 5 years sits at the low end: none of the models tracked here publishes a lower figure.

Running it from a generator

  • Accepts 57–63 Hz (6 Hz wide) — narrow: a generator whose frequency drifts will push it onto battery repeatedly. What transferring means

Noise, temperature and certifications

  • 45 dB — a fan you will hear; closet or rack, not a desk. Among the 11 of 15 models tracked here that publish this figure, values run from 35 dB to 55 dB with a midpoint of 45 dB. This model's 45 dB is within 2% of that midpoint, which is too close to call a difference. Reading noise figures
  • Operating temperature 0 - 40 °C. Batteries age fastest at the top of that range.
  • ENERGY STAR certified, which bounds its own standby draw.
  • Certifications: cTUVus.

What changes in the same capacity range

Compare the published limits before paying for more capacity. A higher power rating alone does not establish longer runtime.

APC SMT750RMI2UNC
  • VA: 750 VA vs 900 VA
  • Watts: 500 W vs 540 W
  • On Battery Waveform: Sine wave vs Stepped approximation to a sinewave
  • UPS Topology: Line interactive vs Standby
APC SMT750RM2UC uninterruptible power supply (UPS) Line-Interactive 0.75 kVA 500 W 6 AC outlet(s)
  • VA: 750 VA vs 900 VA
  • Watts: 500 W vs 540 W
  • On Battery Waveform: Sine wave vs Stepped approximation to a sinewave
  • UPS Topology: Line Interactive vs Standby
APC BR900MI
  • UPS Topology: Line interactive vs Standby
  • AC outlets: 6 vs 8
  • Form factor: Tower vs Compact

Where this model appears next to others

Same figures as above, arranged against a different question.

Full specifications

51 published figures, grouped. The largest groups are open; the rest expand. Each group names where its figures came from.

Power9 figures
VA
900 VA
Watts
540 W
On Battery Waveform
Stepped approximation to a sinewave
UPS Topology
Standby
Typical Transfer Time
6 ms
Input Plug Type
NEMA 5-15P
Nominal Input Voltage
120 V
Surge Suppression (Joules)
490 J
Input Frequency Range
57–63 Hz

APC specification ↗

Features9 figures
Audible alarm modes
Alarm when on battery,Low battery alarm
Audible alarm
Y
Heat dissipation
19.249 BTU/h
Highest input voltage it runs on
120 V
Lowest input voltage it runs on
120 V
Output frequency
50/60 Hz
Output operation voltage max
120 V
Output operation voltage min
120 V
Response time
10 ms

icecat — catalogue values, not manufacturer-checked

Operational conditions6 figures
Non operating altitude
0 - 15240 m
Operating altitude
0 - 3000 m
Operating relative humidity range
0 - 95 %
Operating temperature range
0 - 40 °C
Storage relative humidity range
10 - 90 %
Storage temperature range
-15 - 45 °C

icecat — catalogue values, not manufacturer-checked

Outlets4 figures
Outlet Type
6 NEMA 5-15R, 2 NEMA 5-15R surge
Outlets – Total
8
Outlets – Battery & Surge Protected
6
Outlets – Surge-Only Protected
2

APC specification ↗

Battery4 figures
Typical Recharge Time
8 h
Replacement Battery Cartridge
RBC17
Battery life max
5 year(s)
Battery technology
Lead-acid

APC specification, icecat ↗ — manufacturer-checked and catalogue values, see Sources

Packaging data4 figures
Package depth
382 mm
Package height
225 mm
Package weight
4600 g
Package width
154 mm

icecat — catalogue values, not manufacturer-checked

Weight & dimensions3 figures
Depth
318 mm
Height
90 mm
Width
167 mm

icecat — catalogue values, not manufacturer-checked

Design3 figures
Form factor
Compact
LED indicators
Y
Product colour
Black

icecat — catalogue values, not manufacturer-checked

Ports & interfaces3 figures
Power plug
NEMA 5-15P
USB 2.0 ports
2
USB port
Y

icecat — catalogue values, not manufacturer-checked

Physical2 figures
Physical Weight (lb)
9.04 lb
Cord Length
1.5 m

APC specification ↗

Environment1 figure
Audible Noise
45 dB

APC specification ↗

Certificates1 figure
Compliance certificates
cTUVus

icecat — catalogue values, not manufacturer-checked

Packaging content1 figure
Manual
Y

icecat — catalogue values, not manufacturer-checked

Sustainability1 figure
Sustainability certificates
ENERGY STAR

icecat — catalogue values, not manufacturer-checked

Sources and buying notes

This comparison uses published specifications, not hands-on tests. Prices are listing observations and can change. Read our full methodology.

Before you order

  • Runtime: No load-specific runtime record is available.
  • Startup demand: Startup draw depends on the connected equipment.
  • Equipment compatibility: Confirm plug, voltage, waveform, and both W and VA limits.

Comparison updated October 19, 2026.