UPS battery backup · US 120V
APC SMT750RM2UC
A rack-mount unit for a network cabinet or server rack, sized for the switches, router and servers in it rather than for a desk.
- Capacity
- 750 VA
- Real power limit
- 500 W
- On battery
- Sine wave
- Design
- Line Interactive
Estimated price: about $900 Our estimate for a new unit, from listings seen in November 2026. Not a live price.

Compare new-unit eBay listings
This model has no qualifying listing at the moment. A listing appears here as soon as one does.
We may earn a commission if you buy through these links.
No new unit of this model is listed at a checked price right now. Used and pickup-only listings exist on eBay and are deliberately not shown: every price on this site is a new unit that ships, so a used one has no comparable figure to put beside it. The specifications below are unaffected — they describe the model, not a listing.
What this model actually powers
A limit this size carries a complete desk — desktop, monitors, network — or a living-room setup, with room left over for the storage box beside it.
Each example adds up published power figures for real equipment and compares the total with this model’s 500 W real-power limit as published by the manufacturer. The examples shown are the ones nearest this limit; a bundle far below or far above it would say nothing useful. These are running-load figures, not startup surge, and your own equipment will differ.
Creator workstation, two monitors and a 4-bay NAS
86.2–231.2 W17–46% of this model’s 500 W
about 268.8 W free
Room for one more Mac mini (M4 Pro) idle-to-max (140 W), but not a Mac Studio (M3 Ultra) idle-to-max (270 W).
TV, console and soundbar
247.2–283.2 W49–57% of this model’s 500 W
about 216.8 W free
Room for one more Mac Studio (M4 Max) idle-to-max (145 W), but not a Mac Studio (M3 Ultra) idle-to-max (270 W).
What is in a TV, console and soundbar, and every model measured against it
Home server closet
131.1–294.5 W26–59% of this model’s 500 W
about 205.5 W free
Room for one more Mac Studio (M4 Max) idle-to-max (145 W), but not a Mac Studio (M3 Ultra) idle-to-max (270 W).
High-end workstation with an 8-bay NAS
82.5–377.9 W17–76% of this model’s 500 W
about 122.1 W free
Room for one more desktop 3D printer (120 W), but not a game console (126 W).
Two workstations sharing a NAS
112.2–525.2 W22–105% of this model’s 500 W
more than this model can carry
What is in this example
- Mac Studio (M3 Ultra) idle-to-max power: 9–270 W (source)
- Mac Studio (M4 Max) idle-to-max power: 6–145 W (source)
- 32-inch monitor operating power: 27.8 W (source)
- 27-inch monitor typical and rated power: 20–26 W (source)
- 24-inch monitor typical and rated power: 17–24 W (source)
- 4-bay NAS access power: 32.41 W (source)
A UPS runs longer the less it carries, so a total near the limit buys less time than a light one. Startup draw is not included because it depends on the equipment you connect.
SMT750RM2UC published runtime
Manufacturer reference points, not a runtime guarantee for your setup. Battery age, temperature and equipment load affect results.
Check your equipment load
Start with the watts you know. Add VA from your equipment or meter when available. Each result checks one limit; startup demand and waveform compatibility need separate confirmation.
The W and VA limits used here come from the manufacturer specification.
This model has 6 manufacturer-verified battery-backed outlets. Count plugs connected directly to the UPS. Surge-only outlets do not keep equipment running during an outage. Check adapter spacing in the outlet diagram. View sources
Which outlets stay live
- 6 outlets on battery of 6; every outlet is battery-backed. Among the 9 of 15 models tracked here that publish this figure, values run from 4 to 10 with a midpoint of 5. This model's 6 is above that midpoint.
- Socket type: 6 NEMA 5-15R — household plugs fit directly. Plug families
What replacing the battery costs
- Replacement cartridge RBC109: about $40That is our estimated price for a new part.
- Over five years, one replacement at the rated 6-year life: about $40, 4% of the unit’s own estimated price (about $900).
- Why the battery is a consumable
How long each example would run
From the manufacturer’s runtime curve at half load (16.1 min) and at full load (5.5 min). The curve is the manufacturer’s estimate for new, fully charged batteries, and reads somewhat above the figures datasheets print where both exist. Bounds only.
- Creator workstation, two monitors and a 4-bay NAS at 46% of the limit: at least 16.1 min — it is under half load.
- TV, console and soundbar at 57% of the limit: between 5.5 and 16.1 min.
- Home server closet at 59% of the limit: between 5.5 and 16.1 min.
- High-end workstation with an 8-bay NAS at 76% of the limit: between 5.5 and 16.1 min.
The battery and what replacing it involves
- Sealed Lead Acid (VRLA) (sealed lead-acid — fades over three to five years regardless of use): 1 battery. Why chemistry sets the interval
- Recharge: about 3 h to full. Among the 14 of 15 models tracked here that publish this figure, values run from 3 h to 16 h with a midpoint of 8 h. This model's 3 h sits at the low end: none of the models tracked here publishes a lower figure.
- Rated life: up to 6 years — the replacement interval to budget for. Among the 5 of 15 models tracked here that publish this figure, values run from 5 years to 6 years with a midpoint of 5 years. This model's 6 years sits at the high end: none of the models tracked here publishes a higher figure.
- Hot-swappable: changed under load, no scheduled shutdown. Replacement arrangements
How a computer talks to it
- a USB data port, a card slot. Network management needs the card, sold separately; out of the box one host sees it over USB. USB versus network management
- Front panel: LCD, with an audible alarm; indicators: Status.
What changes in the same capacity range
Compare the published limits before paying for more capacity. A higher power rating alone does not establish longer runtime.
- VA: 900 VA vs 750 VA
- Watts: 540 W vs 500 W
- On Battery Waveform: Stepped approximation to a sinewave vs Sine wave
- UPS Topology: Standby vs Line Interactive
- VA: 900 VA vs 750 VA
- Watts: 540 W vs 500 W
- On Battery Waveform: Stepped approximation to a sinewave vs Sine wave
- UPS Topology: Line interactive vs Line Interactive
Where this model appears next to others
Same figures as above, arranged against a different question.
Full specifications
73 published figures, grouped. The largest groups are open; the rest expand. Each group names where its figures came from.
Features12 figures
- Audible alarm modes
- Alarm when on battery,Low battery alarm
- Audible alarm
- Y
- Auto restart
- Y
- Automatic voltage regulation (AVR)
- Y
- Hold time max
- 10 ms
- Hold time min
- 6 ms
- Highest input voltage it runs on
- 114 V
- Lowest input voltage it runs on
- 82 V
- Output frequency
- 50/60 Hz
- Output operation voltage max
- 127 V
- Output operation voltage min
- 110 V
- Surge protection
- Y
icecat — catalogue values, not manufacturer-checked
Battery10 figures
- Typical Recharge Time
- 3 h
- Replacement Battery Cartridge
- APCRBC123
- Runtime at Half Load
- 16.1 min
- Runtime at Full Load
- 5.5 min
- Automatic battery test
- Y
- Battery life max
- 6 year(s)
- Battery technology
- Sealed Lead Acid (VRLA)
- Cold start
- Y
- Hot swap battery
- Y
- Number of batteries supported
- 1
APC specification, APC runtime curve (estimate), icecat ↗ — manufacturer-checked and catalogue values, see Sources
Power9 figures
- VA
- 750 VA
- Watts
- 500 W
- On Battery Waveform
- Sine wave
- UPS Topology
- Line Interactive
- Typical Transfer Time
- 6 ms
- Input Plug Type
- NEMA 5-15P
- Surge Suppression (Joules)
- 680 J
- Nominal Input Voltage
- 120 V
- Input Frequency Range
- 57–63 Hz
Operational conditions6 figures
- Non operating altitude
- 0 - 15000 m
- Operating altitude
- 0 - 3000 m
- Operating relative humidity range
- 0 - 90 %
- Operating temperature range
- 0 - 40 °C
- Storage relative humidity range
- 0 - 95 %
- Storage temperature range
- -15 - 45 °C
icecat — catalogue values, not manufacturer-checked
Packaging data6 figures
- Package depth
- 570 mm
- Package height
- 235 mm
- Package weight
- 22650 g
- Package width
- 535 mm
- Resource cd
- Y
- Software cd
- Y
icecat — catalogue values, not manufacturer-checked
Design5 figures
- Display type
- LCD
- Form factor
- Rackmount
- LED indicators
- Status
- Product colour
- Black
- Rack capacity
- 2U
icecat — catalogue values, not manufacturer-checked
Ports & interfaces5 figures
- Power plug
- NEMA 5-15P
- Serial interface
- Y
- Serial interface type
- RJ-45
- Smartslot
- Y
- USB port
- Y
icecat — catalogue values, not manufacturer-checked
Outlets4 figures
- Outlets – Total
- 6
- Outlets – Battery & Surge Protected
- 6
- Outlets – Surge-Only Protected
- 0
- Outlet Type
- 6 NEMA 5-15R
Packaging content3 figures
- Cables included
- RS-232,USB cable
- Quick installation guide
- Y
- Rack mount kit
- Y
icecat — catalogue values, not manufacturer-checked
Weight & dimensions3 figures
- Depth
- 409 mm
- Height
- 86 mm
- Width
- 432 mm
icecat — catalogue values, not manufacturer-checked
Certificates2 figures
- Certification
- CSA, CSA C22.2 No. 107.1, FCC Part 15 Class B, ICES-003, UL 1778, REACH
- Compliance certificates
- RoHS
icecat — catalogue values, not manufacturer-checked
Logistics data2 figures
- Harmonized System (HS) code
- 85078000
- Products per pallet
- 16
icecat — catalogue values, not manufacturer-checked
Other features1 figure
- Output voltage
- 120 V
icecat — catalogue values, not manufacturer-checked
Sustainability1 figure
- Sustainability certificates
- ENERGY STAR
icecat — catalogue values, not manufacturer-checked
Sources and buying notes
This comparison uses published specifications, not hands-on tests. Prices are listing observations and can change. Read our full methodology.
- APC specification ↗
Checked 2026-10-19 - APC runtime curve (estimate) ↗
Checked 2026-10-19 - icecat catalogue record
Checked 2026-10-19
Before you order
- Startup demand: Startup draw depends on the connected equipment.
- Equipment compatibility: Confirm plug, voltage, waveform, and both W and VA limits.
Comparison updated October 19, 2026.