UPS battery backup · US 120V

APC SMT750RM2UC

A rack-mount unit for a network cabinet or server rack, sized for the switches, router and servers in it rather than for a desk.

Capacity
750 VA
Real power limit
500 W
On battery
Sine wave
Design
Line Interactive
Check current price on eBay ↗

Estimated price: about $900 Our estimate for a new unit, from listings seen in November 2026. Not a live price.

APC SMT750RM2UC uninterruptible power supply (UPS) Line-Interactive 0.75 kVA 500 W 6 AC outlet(s) uninterruptible power supply
MPN SMT750RM2UC

Compare new-unit eBay listings

This model has no qualifying listing at the moment. A listing appears here as soon as one does.

We may earn a commission if you buy through these links.

No new unit of this model is listed at a checked price right now. Used and pickup-only listings exist on eBay and are deliberately not shown: every price on this site is a new unit that ships, so a used one has no comparable figure to put beside it. The specifications below are unaffected — they describe the model, not a listing.

What this model actually powers

A limit this size carries a complete desk — desktop, monitors, network — or a living-room setup, with room left over for the storage box beside it.

Each example adds up published power figures for real equipment and compares the total with this model’s 500 W real-power limit as published by the manufacturer. The examples shown are the ones nearest this limit; a bundle far below or far above it would say nothing useful. These are running-load figures, not startup surge, and your own equipment will differ.

  • Creator workstation, two monitors and a 4-bay NAS

    86.2–231.2 W17–46% of this model’s 500 W

    about 268.8 W free

    Room for one more Mac mini (M4 Pro) idle-to-max (140 W), but not a Mac Studio (M3 Ultra) idle-to-max (270 W).

    What is in this example
    • Mac Studio (M4 Max) idle-to-max power: 6–145 W (source)
    • 32-inch monitor operating power: 27.8 W (source)
    • 27-inch monitor typical and rated power: 20–26 W (source)
    • 4-bay NAS access power: 32.41 W (source)
  • TV, console and soundbar

    247.2–283.2 W49–57% of this model’s 500 W

    about 216.8 W free

    Room for one more Mac Studio (M4 Max) idle-to-max (145 W), but not a Mac Studio (M3 Ultra) idle-to-max (270 W).

    What is in a TV, console and soundbar, and every model measured against it

  • Home server closet

    131.1–294.5 W26–59% of this model’s 500 W

    about 205.5 W free

    Room for one more Mac Studio (M4 Max) idle-to-max (145 W), but not a Mac Studio (M3 Ultra) idle-to-max (270 W).

    What is in this example
    • 8-bay NAS sleep-to-typical power: 25.668–54.067 W (source)
    • 8-port PoE+ switch maximum power: 90 W (source)
    • Mac mini (M4 Pro) idle-to-max power: 5–140 W (source)
    • Wi-Fi router active power: 5.2 W (source)
    • Cable modem active power: 5.2 W (source)
  • High-end workstation with an 8-bay NAS

    82.5–377.9 W17–76% of this model’s 500 W

    about 122.1 W free

    Room for one more desktop 3D printer (120 W), but not a game console (126 W).

    What is in this example
    • Mac Studio (M3 Ultra) idle-to-max power: 9–270 W (source)
    • 32-inch monitor operating power: 27.8 W (source)
    • 27-inch monitor typical and rated power: 20–26 W (source)
    • 8-bay NAS sleep-to-typical power: 25.668–54.067 W (source)
  • Two workstations sharing a NAS

    112.2–525.2 W22–105% of this model’s 500 W

    more than this model can carry

    What is in this example
    • Mac Studio (M3 Ultra) idle-to-max power: 9–270 W (source)
    • Mac Studio (M4 Max) idle-to-max power: 6–145 W (source)
    • 32-inch monitor operating power: 27.8 W (source)
    • 27-inch monitor typical and rated power: 20–26 W (source)
    • 24-inch monitor typical and rated power: 17–24 W (source)
    • 4-bay NAS access power: 32.41 W (source)

A UPS runs longer the less it carries, so a total near the limit buys less time than a light one. Startup draw is not included because it depends on the equipment you connect.

SMT750RM2UC published runtime

Manufacturer reference points, not a runtime guarantee for your setup. Battery age, temperature and equipment load affect results.

16.1 min50% of rated load
5.5 min100% of rated load

Where these runtime figures come from

Check your equipment load

Start with the watts you know. Add VA from your equipment or meter when available. Each result checks one limit; startup demand and waveform compatibility need separate confirmation.

The W and VA limits used here come from the manufacturer specification.

This model has 6 manufacturer-verified battery-backed outlets. Count plugs connected directly to the UPS. Surge-only outlets do not keep equipment running during an outage. Check adapter spacing in the outlet diagram. View sources

Which outlets stay live

  • 6 outlets on battery of 6; every outlet is battery-backed. Among the 9 of 15 models tracked here that publish this figure, values run from 4 to 10 with a midpoint of 5. This model's 6 is above that midpoint.
  • Socket type: 6 NEMA 5-15R — household plugs fit directly. Plug families

What replacing the battery costs

  • Replacement cartridge RBC109: about $40That is our estimated price for a new part.
  • Over five years, one replacement at the rated 6-year life: about $40, 4% of the unit’s own estimated price (about $900).
  • Why the battery is a consumable

How long each example would run

From the manufacturer’s runtime curve at half load (16.1 min) and at full load (5.5 min). The curve is the manufacturer’s estimate for new, fully charged batteries, and reads somewhat above the figures datasheets print where both exist. Bounds only.

  • Creator workstation, two monitors and a 4-bay NAS at 46% of the limit: at least 16.1 min — it is under half load.
  • TV, console and soundbar at 57% of the limit: between 5.5 and 16.1 min.
  • Home server closet at 59% of the limit: between 5.5 and 16.1 min.
  • High-end workstation with an 8-bay NAS at 76% of the limit: between 5.5 and 16.1 min.

The battery and what replacing it involves

  • Sealed Lead Acid (VRLA) (sealed lead-acid — fades over three to five years regardless of use): 1 battery. Why chemistry sets the interval
  • Recharge: about 3 h to full. Among the 14 of 15 models tracked here that publish this figure, values run from 3 h to 16 h with a midpoint of 8 h. This model's 3 h sits at the low end: none of the models tracked here publishes a lower figure.
  • Rated life: up to 6 years — the replacement interval to budget for. Among the 5 of 15 models tracked here that publish this figure, values run from 5 years to 6 years with a midpoint of 5 years. This model's 6 years sits at the high end: none of the models tracked here publishes a higher figure.
  • Hot-swappable: changed under load, no scheduled shutdown. Replacement arrangements

How a computer talks to it

  • a USB data port, a card slot. Network management needs the card, sold separately; out of the box one host sees it over USB. USB versus network management
  • Front panel: LCD, with an audible alarm; indicators: Status.

What changes in the same capacity range

Compare the published limits before paying for more capacity. A higher power rating alone does not establish longer runtime.

APC BE900G3 uninterruptible power supply (UPS) Standby (Offline) 0.9 kVA 540 W 8 AC outlet(s)
  • VA: 900 VA vs 750 VA
  • Watts: 540 W vs 500 W
  • On Battery Waveform: Stepped approximation to a sinewave vs Sine wave
  • UPS Topology: Standby vs Line Interactive
APC BR900MI
  • VA: 900 VA vs 750 VA
  • Watts: 540 W vs 500 W
  • On Battery Waveform: Stepped approximation to a sinewave vs Sine wave
  • UPS Topology: Line interactive vs Line Interactive

Where this model appears next to others

Same figures as above, arranged against a different question.

Full specifications

73 published figures, grouped. The largest groups are open; the rest expand. Each group names where its figures came from.

Features12 figures
Audible alarm modes
Alarm when on battery,Low battery alarm
Audible alarm
Y
Auto restart
Y
Automatic voltage regulation (AVR)
Y
Hold time max
10 ms
Hold time min
6 ms
Highest input voltage it runs on
114 V
Lowest input voltage it runs on
82 V
Output frequency
50/60 Hz
Output operation voltage max
127 V
Output operation voltage min
110 V
Surge protection
Y

icecat — catalogue values, not manufacturer-checked

Battery10 figures
Typical Recharge Time
3 h
Replacement Battery Cartridge
APCRBC123
Runtime at Half Load
16.1 min
Runtime at Full Load
5.5 min
Automatic battery test
Y
Battery life max
6 year(s)
Battery technology
Sealed Lead Acid (VRLA)
Cold start
Y
Hot swap battery
Y
Number of batteries supported
1

APC specification, APC runtime curve (estimate), icecat ↗ — manufacturer-checked and catalogue values, see Sources

Power9 figures
VA
750 VA
Watts
500 W
On Battery Waveform
Sine wave
UPS Topology
Line Interactive
Typical Transfer Time
6 ms
Input Plug Type
NEMA 5-15P
Surge Suppression (Joules)
680 J
Nominal Input Voltage
120 V
Input Frequency Range
57–63 Hz

APC specification ↗

Operational conditions6 figures
Non operating altitude
0 - 15000 m
Operating altitude
0 - 3000 m
Operating relative humidity range
0 - 90 %
Operating temperature range
0 - 40 °C
Storage relative humidity range
0 - 95 %
Storage temperature range
-15 - 45 °C

icecat — catalogue values, not manufacturer-checked

Packaging data6 figures
Package depth
570 mm
Package height
235 mm
Package weight
22650 g
Package width
535 mm
Resource cd
Y
Software cd
Y

icecat — catalogue values, not manufacturer-checked

Design5 figures
Display type
LCD
Form factor
Rackmount
LED indicators
Status
Product colour
Black
Rack capacity
2U

icecat — catalogue values, not manufacturer-checked

Ports & interfaces5 figures
Power plug
NEMA 5-15P
Serial interface
Y
Serial interface type
RJ-45
Smartslot
Y
USB port
Y

icecat — catalogue values, not manufacturer-checked

Outlets4 figures
Outlets – Total
6
Outlets – Battery & Surge Protected
6
Outlets – Surge-Only Protected
0
Outlet Type
6 NEMA 5-15R

APC specification ↗

Packaging content3 figures
Cables included
RS-232,USB cable
Quick installation guide
Y
Rack mount kit
Y

icecat — catalogue values, not manufacturer-checked

Weight & dimensions3 figures
Depth
409 mm
Height
86 mm
Width
432 mm

icecat — catalogue values, not manufacturer-checked

Physical2 figures
Physical Weight (lb)
39.02 lb
Cord Length
2.4 m

APC specification ↗

Certificates2 figures
Certification
CSA, CSA C22.2 No. 107.1, FCC Part 15 Class B, ICES-003, UL 1778, REACH
Compliance certificates
RoHS

icecat — catalogue values, not manufacturer-checked

Logistics data2 figures
Harmonized System (HS) code
85078000
Products per pallet
16

icecat — catalogue values, not manufacturer-checked

Controls1 figure
LCD
Multi-function LCD status and control console

APC specification ↗

Environment1 figure
Audible Noise
41 dB

APC specification ↗

Other features1 figure
Output voltage
120 V

icecat — catalogue values, not manufacturer-checked

Sustainability1 figure
Sustainability certificates
ENERGY STAR

icecat — catalogue values, not manufacturer-checked

Sources and buying notes

This comparison uses published specifications, not hands-on tests. Prices are listing observations and can change. Read our full methodology.

Before you order

  • Startup demand: Startup draw depends on the connected equipment.
  • Equipment compatibility: Confirm plug, voltage, waveform, and both W and VA limits.

Comparison updated October 19, 2026.