UPS battery backup · US 120V

APC SMTL750RM2UC

A rack-mount unit for a network cabinet or server rack, sized for the switches, router and servers in it rather than for a desk.

Capacity
750 VA
Real power limit
600 W
On battery
Sine wave
Design
Line Interactive
Check current price on eBay ↗

Estimated price: about $1,170 Our estimate for a new unit, from listings seen in November 2026. Not a live price.

APC SMTL750RM2UC uninterruptible power supply (UPS) Line-Interactive 0.75 kVA 600 W 6 AC outlet(s) uninterruptible power supply
MPN SMTL750RM2UC

Compare new-unit eBay listings

This model has no qualifying listing at the moment. A listing appears here as soon as one does.

We may earn a commission if you buy through these links.

No new unit of this model is listed at a checked price right now. Used and pickup-only listings exist on eBay and are deliberately not shown: every price on this site is a new unit that ships, so a used one has no comparable figure to put beside it. The specifications below are unaffected — they describe the model, not a listing.

What this model actually powers

A limit this size carries a complete desk — desktop, monitors, network — or a living-room setup, with room left over for the storage box beside it.

Each example adds up published power figures for real equipment and compares the total with this model’s 600 W real-power limit as published by the manufacturer. The examples shown are the ones nearest this limit; a bundle far below or far above it would say nothing useful. These are running-load figures, not startup surge, and your own equipment will differ.

  • TV, console and soundbar

    247.2–283.2 W41–47% of this model’s 600 W

    about 316.8 W free

    Room for one more Mac Studio (M3 Ultra) idle-to-max (270 W).

    What is in a TV, console and soundbar, and every model measured against it

  • Home server closet

    131.1–294.5 W22–49% of this model’s 600 W

    about 305.5 W free

    Room for one more Mac Studio (M3 Ultra) idle-to-max (270 W).

    What is in this example
    • 8-bay NAS sleep-to-typical power: 25.668–54.067 W (source)
    • 8-port PoE+ switch maximum power: 90 W (source)
    • Mac mini (M4 Pro) idle-to-max power: 5–140 W (source)
    • Wi-Fi router active power: 5.2 W (source)
    • Cable modem active power: 5.2 W (source)
  • High-end workstation with an 8-bay NAS

    82.5–377.9 W14–63% of this model’s 600 W

    about 222.1 W free

    Room for one more Mac Studio (M4 Max) idle-to-max (145 W).

    What is in this example
    • Mac Studio (M3 Ultra) idle-to-max power: 9–270 W (source)
    • 32-inch monitor operating power: 27.8 W (source)
    • 27-inch monitor typical and rated power: 20–26 W (source)
    • 8-bay NAS sleep-to-typical power: 25.668–54.067 W (source)
  • Two workstations sharing a NAS

    112.2–525.2 W19–88% of this model’s 600 W

    about 74.8 W free

    Room for one more Mac mini (M4) idle-to-max (65 W), but not a soundbar system component (75 W).

    What is in this example
    • Mac Studio (M3 Ultra) idle-to-max power: 9–270 W (source)
    • Mac Studio (M4 Max) idle-to-max power: 6–145 W (source)
    • 32-inch monitor operating power: 27.8 W (source)
    • 27-inch monitor typical and rated power: 20–26 W (source)
    • 24-inch monitor typical and rated power: 17–24 W (source)
    • 4-bay NAS access power: 32.41 W (source)
  • Small studio: two desks, storage and network

    182.7–613.1 W30–102% of this model’s 600 W

    more than this model can carry

    What is in this example
    • Mac Studio (M3 Ultra) idle-to-max power: 9–270 W (source)
    • Mac mini (M4 Pro) idle-to-max power: 5–140 W (source)
    • 32-inch monitor operating power: 27.8 W (source)
    • 27-inch monitor typical and rated power: 20–26 W (source)
    • 8-bay NAS sleep-to-typical power: 25.668–54.067 W (source)
    • 8-port PoE+ switch maximum power: 90 W (source)
    • Wi-Fi router active power: 5.2 W (source)

A UPS runs longer the less it carries, so a total near the limit buys less time than a light one. Startup draw is not included because it depends on the equipment you connect.

SMTL750RM2UC published runtime

Manufacturer reference points, not a runtime guarantee for your setup. Battery age, temperature and equipment load affect results.

12.9 min50% of rated load
6.2 min100% of rated load

Where these runtime figures come from

Check your equipment load

Start with the watts you know. Add VA from your equipment or meter when available. Each result checks one limit; startup demand and waveform compatibility need separate confirmation.

The W and VA limits used here come from the manufacturer specification.

This model has 6 manufacturer-verified battery-backed outlets. Count plugs connected directly to the UPS. Surge-only outlets do not keep equipment running during an outage. Check adapter spacing in the outlet diagram. View sources

Which outlets stay live

  • 6 outlets on battery of 6; every outlet is battery-backed. Among the 14 of 15 models tracked here that publish this figure, values run from 4 to 10 with a midpoint of 6.5. This model's 6 is below that midpoint.
  • Socket type: 6 NEMA 5-15R — household plugs fit directly. Plug families

How long each example would run

From the manufacturer’s runtime curve at half load (12.9 min) and at full load (6.2 min). The curve is the manufacturer’s estimate for new, fully charged batteries, and reads somewhat above the figures datasheets print where both exist. Bounds only.

  • TV, console and soundbar at 47% of the limit: at least 12.9 min — it is under half load.
  • Home server closet at 49% of the limit: at least 12.9 min — it is under half load.
  • High-end workstation with an 8-bay NAS at 63% of the limit: between 6.2 and 12.9 min.
  • Two workstations sharing a NAS at 88% of the limit: between 6.2 and 12.9 min.

The battery and what replacing it involves

  • Lithium-Ion (Li-Ion) (lithium — more cycles, faster recharge, higher price): 150 Ah. Why chemistry sets the interval
  • Recharge: about 3 h to full. Among the 15 of 15 models tracked here that publish this figure, values run from 1.5 h to 8 h with a midpoint of 3 h. This model's 3 h is within 2% of that midpoint, which is too close to call a difference.
  • Rated life: up to 10 years — the replacement interval to budget for. Among the 8 of 15 models tracked here that publish this figure, values run from 5 years to 10 years with a midpoint of 5.5 years. This model's 10 years sits at the high end: none of the models tracked here publishes a higher figure.
  • Hot-swappable: changed under load, no scheduled shutdown. Replacement arrangements

How a computer talks to it

  • a USB data port, a card slot. Network management needs the card, sold separately; out of the box one host sees it over USB. USB versus network management
  • Front panel: LCD, with an audible alarm.

Running it from a generator

  • Accepts 57–63 Hz (6 Hz wide) — narrow: a generator whose frequency drifts will push it onto battery repeatedly. What transferring means

What changes in the same capacity range

Compare the published limits before paying for more capacity. A higher power rating alone does not establish longer runtime.

APC BE850G2 uninterruptible power supply (UPS) Standby (Offline) 0.85 kVA 450 W 9 AC outlet(s)
  • VA: 850 VA vs 750 VA
  • Watts: 450 W vs 600 W
  • On Battery Waveform: Stepped approximation to a sinewave vs Sine wave
  • UPS Topology: Standby vs Line Interactive
APC SMX750C uninterruptible power supply (UPS) Line-Interactive 0.75 kVA 675 W 8 AC outlet(s)
  • Watts: 675 W vs 600 W
  • Outlets – Total: 8 vs 6
  • Form factor: Rackmount/Tower vs Rackmount

Where this model appears next to others

Same figures as above, arranged against a different question.

Full specifications

61 published figures, grouped. The largest groups are open; the rest expand. Each group names where its figures came from.

Power9 figures
VA
750 VA
Watts
600 W
On Battery Waveform
Sine wave
UPS Topology
Line Interactive
Typical Transfer Time
6 ms
Input Plug Type
NEMA 5-15P
Nominal Input Voltage
120 V
Surge Suppression (Joules)
680 J
Input Frequency Range
57–63 Hz

APC specification ↗

Battery8 figures
Typical Recharge Time
3 h
Runtime at Half Load
12.9 min
Runtime at Full Load
6.2 min
Battery capacity
150 Ah
Battery life max
10 year(s)
Battery technology
Lithium-Ion (Li-Ion)
Cold start
Y
Hot swap battery
Y

APC specification, APC runtime curve (estimate), icecat ↗ — manufacturer-checked and catalogue values, see Sources

Features8 figures
Audible alarm modes
Alarm when on battery,Low battery alarm,Overload alarm
Audible alarm
Y
Efficiency
96 %
Emergency power off (EPO)
Y
Highest input voltage it runs on
144 V
Lowest input voltage it runs on
82 V
Output voltage distortion (THD)
5 %
Response time
6 ms

icecat — catalogue values, not manufacturer-checked

Operational conditions6 figures
Non operating altitude
0 - 15000 m
Operating altitude
0 - 3000 m
Operating relative humidity range
0 - 95 %
Operating temperature range
0 - 40 °C
Storage relative humidity range
0 - 95 %
Storage temperature range
-15 - 45 °C

icecat — catalogue values, not manufacturer-checked

Design5 figures
Display type
LCD
Form factor
Rackmount
LED indicators
Y
Product colour
Black,Silver
Rack capacity
2U

icecat — catalogue values, not manufacturer-checked

Ports & interfaces5 figures
Power plug
NEMA 5-15P
Serial interface
Y
Serial interface type
RJ-45
Smartslot
Y
USB port
Y

icecat — catalogue values, not manufacturer-checked

Outlets4 figures
Outlet Type
6 NEMA 5-15R
Outlets – Total
6
Outlets – Battery & Surge Protected
6
Outlets – Surge-Only Protected
0

APC specification ↗

Packaging content4 figures
Cables included
RS-232,USB cable
Manual
Y
Quick installation guide
Y
Rack mount kit
Y

icecat — catalogue values, not manufacturer-checked

Packaging data4 figures
Package depth
472 mm
Package height
229 mm
Package weight
17690 g
Package width
584 mm

icecat — catalogue values, not manufacturer-checked

Weight & dimensions3 figures
Depth
318 mm
Height
86 mm
Width
438 mm

icecat — catalogue values, not manufacturer-checked

Physical2 figures
Physical Weight (lb)
34.00 lb
Cord Length
2.4 m

APC specification ↗

Environment1 figure
Audible Noise
41 dB

APC specification ↗

Controls1 figure
LCD
Multi-function LCD status and control console

APC specification ↗

Certificates1 figure
Compliance certificates
RoHS

icecat — catalogue values, not manufacturer-checked

Sources and buying notes

This comparison uses published specifications, not hands-on tests. Prices are listing observations and can change. Read our full methodology.

Before you order

  • Startup demand: Startup draw depends on the connected equipment.
  • Equipment compatibility: Confirm plug, voltage, waveform, and both W and VA limits.

Comparison updated October 19, 2026.