UPS battery backup · US 120V
APC SMTL750RM2UC
A rack-mount unit for a network cabinet or server rack, sized for the switches, router and servers in it rather than for a desk.
- Capacity
- 750 VA
- Real power limit
- 600 W
- On battery
- Sine wave
- Design
- Line Interactive
Estimated price: about $1,170 Our estimate for a new unit, from listings seen in November 2026. Not a live price.

Compare new-unit eBay listings
This model has no qualifying listing at the moment. A listing appears here as soon as one does.
We may earn a commission if you buy through these links.
No new unit of this model is listed at a checked price right now. Used and pickup-only listings exist on eBay and are deliberately not shown: every price on this site is a new unit that ships, so a used one has no comparable figure to put beside it. The specifications below are unaffected — they describe the model, not a listing.
What this model actually powers
A limit this size carries a complete desk — desktop, monitors, network — or a living-room setup, with room left over for the storage box beside it.
Each example adds up published power figures for real equipment and compares the total with this model’s 600 W real-power limit as published by the manufacturer. The examples shown are the ones nearest this limit; a bundle far below or far above it would say nothing useful. These are running-load figures, not startup surge, and your own equipment will differ.
TV, console and soundbar
247.2–283.2 W41–47% of this model’s 600 W
about 316.8 W free
Room for one more Mac Studio (M3 Ultra) idle-to-max (270 W).
What is in a TV, console and soundbar, and every model measured against it
Home server closet
131.1–294.5 W22–49% of this model’s 600 W
about 305.5 W free
Room for one more Mac Studio (M3 Ultra) idle-to-max (270 W).
High-end workstation with an 8-bay NAS
82.5–377.9 W14–63% of this model’s 600 W
about 222.1 W free
Room for one more Mac Studio (M4 Max) idle-to-max (145 W).
Two workstations sharing a NAS
112.2–525.2 W19–88% of this model’s 600 W
about 74.8 W free
Room for one more Mac mini (M4) idle-to-max (65 W), but not a soundbar system component (75 W).
What is in this example
- Mac Studio (M3 Ultra) idle-to-max power: 9–270 W (source)
- Mac Studio (M4 Max) idle-to-max power: 6–145 W (source)
- 32-inch monitor operating power: 27.8 W (source)
- 27-inch monitor typical and rated power: 20–26 W (source)
- 24-inch monitor typical and rated power: 17–24 W (source)
- 4-bay NAS access power: 32.41 W (source)
Small studio: two desks, storage and network
182.7–613.1 W30–102% of this model’s 600 W
more than this model can carry
What is in this example
- Mac Studio (M3 Ultra) idle-to-max power: 9–270 W (source)
- Mac mini (M4 Pro) idle-to-max power: 5–140 W (source)
- 32-inch monitor operating power: 27.8 W (source)
- 27-inch monitor typical and rated power: 20–26 W (source)
- 8-bay NAS sleep-to-typical power: 25.668–54.067 W (source)
- 8-port PoE+ switch maximum power: 90 W (source)
- Wi-Fi router active power: 5.2 W (source)
A UPS runs longer the less it carries, so a total near the limit buys less time than a light one. Startup draw is not included because it depends on the equipment you connect.
SMTL750RM2UC published runtime
Manufacturer reference points, not a runtime guarantee for your setup. Battery age, temperature and equipment load affect results.
Check your equipment load
Start with the watts you know. Add VA from your equipment or meter when available. Each result checks one limit; startup demand and waveform compatibility need separate confirmation.
The W and VA limits used here come from the manufacturer specification.
This model has 6 manufacturer-verified battery-backed outlets. Count plugs connected directly to the UPS. Surge-only outlets do not keep equipment running during an outage. Check adapter spacing in the outlet diagram. View sources
Which outlets stay live
- 6 outlets on battery of 6; every outlet is battery-backed. Among the 14 of 15 models tracked here that publish this figure, values run from 4 to 10 with a midpoint of 6.5. This model's 6 is below that midpoint.
- Socket type: 6 NEMA 5-15R — household plugs fit directly. Plug families
How long each example would run
From the manufacturer’s runtime curve at half load (12.9 min) and at full load (6.2 min). The curve is the manufacturer’s estimate for new, fully charged batteries, and reads somewhat above the figures datasheets print where both exist. Bounds only.
- TV, console and soundbar at 47% of the limit: at least 12.9 min — it is under half load.
- Home server closet at 49% of the limit: at least 12.9 min — it is under half load.
- High-end workstation with an 8-bay NAS at 63% of the limit: between 6.2 and 12.9 min.
- Two workstations sharing a NAS at 88% of the limit: between 6.2 and 12.9 min.
The battery and what replacing it involves
- Lithium-Ion (Li-Ion) (lithium — more cycles, faster recharge, higher price): 150 Ah. Why chemistry sets the interval
- Recharge: about 3 h to full. Among the 15 of 15 models tracked here that publish this figure, values run from 1.5 h to 8 h with a midpoint of 3 h. This model's 3 h is within 2% of that midpoint, which is too close to call a difference.
- Rated life: up to 10 years — the replacement interval to budget for. Among the 8 of 15 models tracked here that publish this figure, values run from 5 years to 10 years with a midpoint of 5.5 years. This model's 10 years sits at the high end: none of the models tracked here publishes a higher figure.
- Hot-swappable: changed under load, no scheduled shutdown. Replacement arrangements
How a computer talks to it
- a USB data port, a card slot. Network management needs the card, sold separately; out of the box one host sees it over USB. USB versus network management
- Front panel: LCD, with an audible alarm.
Running it from a generator
- Accepts 57–63 Hz (6 Hz wide) — narrow: a generator whose frequency drifts will push it onto battery repeatedly. What transferring means
What changes in the same capacity range
Compare the published limits before paying for more capacity. A higher power rating alone does not establish longer runtime.
- VA: 850 VA vs 750 VA
- Watts: 450 W vs 600 W
- On Battery Waveform: Stepped approximation to a sinewave vs Sine wave
- UPS Topology: Standby vs Line Interactive
- Watts: 675 W vs 600 W
- Outlets – Total: 8 vs 6
- Form factor: Rackmount/Tower vs Rackmount
Where this model appears next to others
Same figures as above, arranged against a different question.
Full specifications
61 published figures, grouped. The largest groups are open; the rest expand. Each group names where its figures came from.
Power9 figures
- VA
- 750 VA
- Watts
- 600 W
- On Battery Waveform
- Sine wave
- UPS Topology
- Line Interactive
- Typical Transfer Time
- 6 ms
- Input Plug Type
- NEMA 5-15P
- Nominal Input Voltage
- 120 V
- Surge Suppression (Joules)
- 680 J
- Input Frequency Range
- 57–63 Hz
Battery8 figures
- Typical Recharge Time
- 3 h
- Runtime at Half Load
- 12.9 min
- Runtime at Full Load
- 6.2 min
- Battery capacity
- 150 Ah
- Battery life max
- 10 year(s)
- Battery technology
- Lithium-Ion (Li-Ion)
- Cold start
- Y
- Hot swap battery
- Y
APC specification, APC runtime curve (estimate), icecat ↗ — manufacturer-checked and catalogue values, see Sources
Features8 figures
- Audible alarm modes
- Alarm when on battery,Low battery alarm,Overload alarm
- Audible alarm
- Y
- Efficiency
- 96 %
- Emergency power off (EPO)
- Y
- Highest input voltage it runs on
- 144 V
- Lowest input voltage it runs on
- 82 V
- Output voltage distortion (THD)
- 5 %
- Response time
- 6 ms
icecat — catalogue values, not manufacturer-checked
Operational conditions6 figures
- Non operating altitude
- 0 - 15000 m
- Operating altitude
- 0 - 3000 m
- Operating relative humidity range
- 0 - 95 %
- Operating temperature range
- 0 - 40 °C
- Storage relative humidity range
- 0 - 95 %
- Storage temperature range
- -15 - 45 °C
icecat — catalogue values, not manufacturer-checked
Design5 figures
- Display type
- LCD
- Form factor
- Rackmount
- LED indicators
- Y
- Product colour
- Black,Silver
- Rack capacity
- 2U
icecat — catalogue values, not manufacturer-checked
Ports & interfaces5 figures
- Power plug
- NEMA 5-15P
- Serial interface
- Y
- Serial interface type
- RJ-45
- Smartslot
- Y
- USB port
- Y
icecat — catalogue values, not manufacturer-checked
Outlets4 figures
- Outlet Type
- 6 NEMA 5-15R
- Outlets – Total
- 6
- Outlets – Battery & Surge Protected
- 6
- Outlets – Surge-Only Protected
- 0
Packaging content4 figures
- Cables included
- RS-232,USB cable
- Manual
- Y
- Quick installation guide
- Y
- Rack mount kit
- Y
icecat — catalogue values, not manufacturer-checked
Packaging data4 figures
- Package depth
- 472 mm
- Package height
- 229 mm
- Package weight
- 17690 g
- Package width
- 584 mm
icecat — catalogue values, not manufacturer-checked
Weight & dimensions3 figures
- Depth
- 318 mm
- Height
- 86 mm
- Width
- 438 mm
icecat — catalogue values, not manufacturer-checked
Certificates1 figure
- Compliance certificates
- RoHS
icecat — catalogue values, not manufacturer-checked
Sources and buying notes
This comparison uses published specifications, not hands-on tests. Prices are listing observations and can change. Read our full methodology.
- APC specification ↗
Checked 2026-10-19 - APC runtime curve (estimate) ↗
Checked 2026-10-19 - icecat catalogue record
Checked 2026-10-19
Before you order
- Startup demand: Startup draw depends on the connected equipment.
- Equipment compatibility: Confirm plug, voltage, waveform, and both W and VA limits.
Comparison updated October 19, 2026.