UPS battery backup · US 120V

APC SMX750C

A rack-mount unit for a network cabinet or server rack, sized for the switches, router and servers in it rather than for a desk.

Capacity
750 VA
Real power limit
675 W
On battery
Sine wave
Design
Line Interactive
Check current price on eBay ↗

Estimated price: about $500 Our estimate for a new unit, from listings seen in November 2026. Not a live price.

APC SMX750C uninterruptible power supply (UPS) Line-Interactive 0.75 kVA 675 W 8 AC outlet(s) uninterruptible power supply
MPN SMX750C

Compare new-unit eBay listings

This model has no qualifying listing at the moment. A listing appears here as soon as one does.

We may earn a commission if you buy through these links.

No new unit of this model is listed at a checked price right now. Used and pickup-only listings exist on eBay and are deliberately not shown: every price on this site is a new unit that ships, so a used one has no comparable figure to put beside it. The specifications below are unaffected — they describe the model, not a listing.

What this model actually powers

A limit this size carries a complete desk — desktop, monitors, network — or a living-room setup, with room left over for the storage box beside it.

Each example adds up published power figures for real equipment and compares the total with this model’s 675 W real-power limit as published by the manufacturer. The examples shown are the ones nearest this limit; a bundle far below or far above it would say nothing useful. These are running-load figures, not startup surge, and your own equipment will differ.

  • TV, console and soundbar

    247.2–283.2 W37–42% of this model’s 675 W

    about 391.8 W free

    Room for one more Mac Studio (M3 Ultra) idle-to-max (270 W).

    What is in a TV, console and soundbar, and every model measured against it

  • Home server closet

    131.1–294.5 W19–44% of this model’s 675 W

    about 380.5 W free

    Room for one more Mac Studio (M3 Ultra) idle-to-max (270 W).

    What is in this example
    • 8-bay NAS sleep-to-typical power: 25.668–54.067 W (source)
    • 8-port PoE+ switch maximum power: 90 W (source)
    • Mac mini (M4 Pro) idle-to-max power: 5–140 W (source)
    • Wi-Fi router active power: 5.2 W (source)
    • Cable modem active power: 5.2 W (source)
  • High-end workstation with an 8-bay NAS

    82.5–377.9 W12–56% of this model’s 675 W

    about 297.1 W free

    Room for 2 more loads the size of a Mac Studio (M4 Max) idle-to-max (145 W each).

    What is in this example
    • Mac Studio (M3 Ultra) idle-to-max power: 9–270 W (source)
    • 32-inch monitor operating power: 27.8 W (source)
    • 27-inch monitor typical and rated power: 20–26 W (source)
    • 8-bay NAS sleep-to-typical power: 25.668–54.067 W (source)
  • Two workstations sharing a NAS

    112.2–525.2 W17–78% of this model’s 675 W

    about 149.8 W free

    Room for one more Mac mini (M4 Pro) idle-to-max (140 W).

    What is in this example
    • Mac Studio (M3 Ultra) idle-to-max power: 9–270 W (source)
    • Mac Studio (M4 Max) idle-to-max power: 6–145 W (source)
    • 32-inch monitor operating power: 27.8 W (source)
    • 27-inch monitor typical and rated power: 20–26 W (source)
    • 24-inch monitor typical and rated power: 17–24 W (source)
    • 4-bay NAS access power: 32.41 W (source)
  • Small studio: two desks, storage and network

    182.7–613.1 W27–91% of this model’s 675 W

    about 61.9 W free

    Room for one more 4-bay NAS (32.41 W), but not a Mac mini (M4) idle-to-max (65 W).

    What is in this example
    • Mac Studio (M3 Ultra) idle-to-max power: 9–270 W (source)
    • Mac mini (M4 Pro) idle-to-max power: 5–140 W (source)
    • 32-inch monitor operating power: 27.8 W (source)
    • 27-inch monitor typical and rated power: 20–26 W (source)
    • 8-bay NAS sleep-to-typical power: 25.668–54.067 W (source)
    • 8-port PoE+ switch maximum power: 90 W (source)
    • Wi-Fi router active power: 5.2 W (source)

A UPS runs longer the less it carries, so a total near the limit buys less time than a light one. Startup draw is not included because it depends on the equipment you connect.

SMX750C published runtime

Manufacturer reference points, not a runtime guarantee for your setup. Battery age, temperature and equipment load affect results.

27 min50% of rated load
11.5 min100% of rated load

Where these runtime figures come from

Check your equipment load

Start with the watts you know. Add VA from your equipment or meter when available. Each result checks one limit; startup demand and waveform compatibility need separate confirmation.

The W and VA limits used here come from the manufacturer specification.

This model has 8 manufacturer-verified battery-backed outlets. Count plugs connected directly to the UPS. Surge-only outlets do not keep equipment running during an outage. Check adapter spacing in the outlet diagram. View sources

Which outlets stay live

  • 8 outlets on battery of 8; every outlet is battery-backed. Among the 14 of 15 models tracked here that publish this figure, values run from 4 to 10 with a midpoint of 6.5. This model's 8 is above that midpoint.
  • Socket type: 8 NEMA 5-15R — household plugs fit directly. Plug families

What replacing the battery costs

  • Replacement cartridge RBC116: about $130That is our estimated price for a new part.
  • Over five years, one replacement at the three-to-five-year interval sealed batteries are rated for: about $130, 26% of the unit’s own estimated price (about $500).
  • Why the battery is a consumable

How long each example would run

From the published runtime at half load (27 min) and at full load (11.5 min). Bounds only: the site does not estimate between two measurements it did not take.

  • TV, console and soundbar at 42% of the limit: at least 27 min — it is under half load.
  • Home server closet at 44% of the limit: at least 27 min — it is under half load.
  • High-end workstation with an 8-bay NAS at 56% of the limit: between 11.5 and 27 min.
  • Two workstations sharing a NAS at 78% of the limit: between 11.5 and 27 min.
  • Small studio: two desks, storage and network at 91% of the limit: between 11.5 and 27 min.

Running it from a generator

  • Accepts 57–63 Hz (6 Hz wide) — narrow: a generator whose frequency drifts will push it onto battery repeatedly. What transferring means

Where it fits and what it weighs

  • Rack space: 2U, so it occupies exactly 3.5 in of rack height, and needs at least 19.3 in of clear depth behind the rails.
  • Weight: 48.6 lb (22 kg). Check the load rating of a wall shelf or rail kit before mounting.
  • Form factor: Rackmount/Tower — the same chassis mounts flat in a rack or stands on end, so one purchase covers either plan.

Published as 89 × 490 × 432 mm and 48.61 lb. Converted here using 1 in = 25.4 mm. Shipping weight and box size are larger.

What changes in the same capacity range

Compare the published limits before paying for more capacity. A higher power rating alone does not establish longer runtime.

APC BE850G2 uninterruptible power supply (UPS) Standby (Offline) 0.85 kVA 450 W 9 AC outlet(s)
  • VA: 850 VA vs 750 VA
  • Watts: 450 W vs 675 W
  • On Battery Waveform: Stepped approximation to a sinewave vs Sine wave
  • UPS Topology: Standby vs Line Interactive
APC SMTL750RM2UC uninterruptible power supply (UPS) Line-Interactive 0.75 kVA 600 W 6 AC outlet(s)
  • Watts: 600 W vs 675 W
  • Outlets – Total: 6 vs 8
  • Form factor: Rackmount vs Rackmount/Tower

Where this model appears next to others

Same figures as above, arranged against a different question.

Full specifications

46 published figures, grouped. The largest groups are open; the rest expand. Each group names where its figures came from.

Power8 figures
VA
750 VA
Watts
675 W
On Battery Waveform
Sine wave
UPS Topology
Line Interactive
Input Plug Type
NEMA 5-15P
Nominal Input Voltage
120 V
Surge Suppression (Joules)
645 J
Input Frequency Range
57–63 Hz

APC specification ↗

Features8 figures
Audible alarm
Y
Emergency power off (EPO)
Y
Highest input voltage it runs on
154 V
Lowest input voltage it runs on
75 V
Maximum current
12 A
Output operation voltage max
120 V
Output operation voltage min
120 V
Output voltage distortion (THD)
5 %

icecat — catalogue values, not manufacturer-checked

Operational conditions6 figures
Non operating altitude
0 - 15240 m
Operating altitude
0 - 3048 m
Operating relative humidity range
0 - 95 %
Operating temperature range
0 - 40 °C
Storage relative humidity range
0 - 95 %
Storage temperature range
-15 - 45 °C

icecat — catalogue values, not manufacturer-checked

Battery5 figures
Typical Recharge Time
3 h
Replacement Battery Cartridge
APCRBC116
Runtime at Half Load
27 min
Runtime at Full Load
11.5 min
Battery technology
Sealed Lead Acid (VRLA)

APC specification, icecat ↗ — manufacturer-checked and catalogue values, see Sources

Design5 figures
Display type
LCD
Form factor
Rackmount/Tower
LED indicators
Y
Product colour
Black
Rack capacity
2U

icecat — catalogue values, not manufacturer-checked

Outlets4 figures
Outlet Type
8 NEMA 5-15R
Outlets – Total
8
Outlets – Battery & Surge Protected
8
Outlets – Surge-Only Protected
0

APC specification ↗

Packaging data4 figures
Package depth
620 mm
Package height
589 mm
Package weight
26500 g
Package width
246 mm

icecat — catalogue values, not manufacturer-checked

Weight & dimensions3 figures
Depth
490 mm
Height
432 mm
Width
89 mm

icecat — catalogue values, not manufacturer-checked

Physical2 figures
Physical Weight (lb)
48.61 lb
Cord Length
2.4 m

APC specification ↗

Environment1 figure
Audible Noise
40 dB

APC specification ↗

Sources and buying notes

This comparison uses published specifications, not hands-on tests. Prices are listing observations and can change. Read our full methodology.

Before you order

  • Startup demand: Startup draw depends on the connected equipment.
  • Equipment compatibility: Confirm plug, voltage, waveform, and both W and VA limits.

Comparison updated October 19, 2026.