UPS battery backup · US 120V

CyberPower AVRG750U uninterruptible power supply (UPS) 0.75 kVA 450 W 12 AC outlet(s) vs CyberPower EC650LCD

Which one to buy depends on what you plug in and what you pay. Below: the setups one carries and the other cannot, the price per watt, the replacement battery, and every published specification where they differ. No unit was tested here; every figure is from the model’s own page.

Which one to choose

  • Choose the AVRG750U if outlets – total and outlets – battery & surge protected matter to you (more outlets in total; more plugs stay powered during an outage).
  • Choose the EC650LCD if price decides: it is about $50 less by our price estimates; or if runtime at half load and runtime at full load matter to you (longer published runtime at the same share of its rating; longer published runtime at full load).

What it costs to own

CostAVRG750UEC650LCD
Price per watt of capacityAbout $0.29 per WAbout $0.21 per W
Replacement batteryRB1270B-UPC, est. about $40Not published

CyberPower

CyberPower AVRG750U uninterruptible power supply (UPS) 0.75 kVA 450 W 12 AC outlet(s)

Real power limit
450 W
Rated capacity
750 VA
Estimated price
Est. about $130
Full specs and prices →

Where they differ

SpecificationAVRG750UEC650LCDWhat the difference means
Watts450 W390 WAVRG750U: more real-power headroom for the same equipment
VA750 VA650 VAAVRG750U: a higher rating, though watts is the figure to size against
UPS TopologyLine InteractiveStandbyline-interactive corrects sags and surges without draining the battery; standby switches to battery for them
Outlets – Total128AVRG750U: more outlets in total
Outlets – Battery & Surge Protected64AVRG750U: more plugs stay powered during an outage
Outlet Type12 – NEMA 5-15R8 – NEMA 5-15Rdecides which plugs fit without an adapter
Runtime at Half Load7.6 min8.4 minEC650LCD: longer published runtime at the same share of its rating
Runtime at Full Load2.5 min2.8 minEC650LCD: longer published runtime at full load
Surge Suppression (Joules)1030 J526 JAVRG750U: more surge energy absorbed over the unit’s life
User Replaceable BatteryYesNodecides whether you can swap the battery yourself
Physical Weight (lb)13.44 lb6.4 lbmatters for where it sits and how it ships, not for what it can carry

What the choice is not about

Both models publish the same value for these, so they cannot decide it either way.

  • On Battery Waveform: Simulated Sine Wave
  • Input Plug Type: NEMA 5-15P
  • Battery Type: Sealed Lead-Acid Battery
  • Form Factor: Compact

Neither of these? every 600VA model and every 850VA model are on one page, with the same figures and an estimated price for each.