UPS battery backup · US 120V
CyberPower CP850AVRLCD vs Vertiv PowerUPS 200 Line Interactive PSA6-850LVT, 850VA/530W, AVR, USB Charging, Color LCD, User-Replaceable Battery, 6 NEMA Outlets, Three-Year Warranty
Which one to buy depends on what you plug in and what you pay. Below: the setups one carries and the other cannot, the price per watt, the replacement battery, and every published specification where they differ. No unit was tested here; every figure is from the model’s own page.
Which one to choose
- Choose the CP850AVRLCD if outlets – total and runtime at half load matter to you (more outlets in total; longer published runtime at the same share of its rating).
- Choose the PSA6-850LVT if you need to run a two workstations sharing a nas (about 525.2 W), which the CP850AVRLCD cannot carry; or if surge suppression (joules) matter to you (more surge energy absorbed over the unit’s life).
Setups that separate them
Each setup’s draw is the sum of published figures for its devices, the same totals the model pages use. A unit is roomy at 80% of its watt limit or less, tight above that, and short when the load exceeds the limit.
| Setup | CP850AVRLCD | PSA6-850LVT |
|---|---|---|
| Two workstations sharing a NAS (up to 525.2 W) | Cannot carry (103% of limit) | Tight (99% of limit) |
What it costs to own
| Cost | CP850AVRLCD | PSA6-850LVT |
|---|---|---|
| Price per watt of capacity | No estimate | About $0.32 per W |
| Replacement battery | RB1290 | Not published |
CyberPower
CyberPower CP850AVRLCD
- Real power limit
- 510 W
- Rated capacity
- 850 VA
- Estimated price
- Check current price
Vertiv
Vertiv PowerUPS 200 Line Interactive PSA6-850LVT, 850VA/530W, AVR, USB Charging, Color LCD, User-Replaceable Battery, 6 NEMA Outlets, Three-Year Warranty
- Real power limit
- 530 W
- Rated capacity
- 850 VA
- Estimated price
- Est. about $170
Where they differ
| Specification | CP850AVRLCD | PSA6-850LVT | What the difference means |
|---|---|---|---|
| Watts | 510 W | 530 W | PSA6-850LVT: more real-power headroom for the same equipment |
| On Battery Waveform | Simulated Sine Wave | Simulated Sine wave | matters for equipment with active-PFC power supplies, which prefer a sine wave |
| UPS Topology | Line Interactive | Line-interactive | line-interactive corrects sags and surges without draining the battery; standby switches to battery for them |
| Outlets – Total | 9 | 8 | CP850AVRLCD: more outlets in total |
| Runtime at Half Load | 11 min | 8 min | CP850AVRLCD: longer published runtime at the same share of its rating |
| Runtime at Full Load | 3 min | 1.8 min | CP850AVRLCD: longer published runtime at full load |
| Surge Suppression (Joules) | 1080 J | 1200 J | PSA6-850LVT: more surge energy absorbed over the unit’s life |
| Form Factor | Mini-Tower | Tower | decides where it fits: on a desk, on the floor or in a rack |
| Physical Weight (lb) | 15 lb | 17.2 lb | matters for where it sits and how it ships, not for what it can carry |
Neither of these? every 850VA model is on one page, with the same figures and an estimated price for each.
Both records come from this site’s pages for the CP850AVRLCD and the PSA6-850LVT, where every figure carries its source. Read our methodology.