UPS battery backup · US 120V

CyberPower OR1000LCDRM1U vs CyberPower PR1000LCDRT1U uninterruptible power supply (UPS) Line-Interactive 1 kVA 800 W 7 AC outlet(s)

Which one to buy depends on what you plug in and what you pay. Below: the setups one carries and the other cannot, the price per watt, the replacement battery, and every published specification where they differ. No unit was tested here; every figure is from the model’s own page.

Which one to choose

  • Choose the OR1000LCDRM1U if price decides: it is about $190 less by our price estimates; or if typical transfer time and surge suppression (joules) matter to you (less time without power when it switches to battery; more surge energy absorbed over the unit’s life).
  • Choose the PR1000LCDRT1U if you need to run a small studio: two desks, storage and network (about 613.1 W), which the OR1000LCDRM1U cannot carry; or if output power factor and outlets – total matter to you (more of the rating is usable as real power; more outlets in total).

Setups that separate them

Each setup’s draw is the sum of published figures for its devices, the same totals the model pages use. A unit is roomy at 80% of its watt limit or less, tight above that, and short when the load exceeds the limit.

SetupOR1000LCDRM1UPR1000LCDRT1U
Two workstations sharing a NAS (up to 525.2 W)Tight (88% of limit)Roomy (66% of limit)
Small studio: two desks, storage and network (up to 613.1 W)Cannot carry (102% of limit)Roomy (77% of limit)

What it costs to own

CostOR1000LCDRM1UPR1000LCDRT1U
Price per watt of capacityAbout $0.85 per WAbout $0.88 per W
Replacement batteryRB0670X4, est. about $70RB0690X4B, est. about $130

CyberPower

CyberPower OR1000LCDRM1U

Real power limit
600 W
Rated capacity
1000 VA
Estimated price
Est. about $510
Full specs and prices →

CyberPower

CyberPower PR1000LCDRT1U uninterruptible power supply (UPS) Line-Interactive 1 kVA 800 W 7 AC outlet(s)

Real power limit
800 W
Rated capacity
1000 VA
Estimated price
Est. about $700
Full specs and prices →

Where they differ

SpecificationOR1000LCDRM1UPR1000LCDRT1UWhat the difference means
Watts600 W800 WPR1000LCDRT1U: more real-power headroom for the same equipment
On Battery WaveformSimulated Sine WaveSine Wavematters for equipment with active-PFC power supplies, which prefer a sine wave
Typical Transfer Time8 ms10 msOR1000LCDRM1U: less time without power when it switches to battery
Output Power Factor0.60.8PR1000LCDRT1U: more of the rating is usable as real power
Outlets – Total67PR1000LCDRT1U: more outlets in total
Outlets – Battery & Surge Protected46PR1000LCDRT1U: more plugs stay powered during an outage
Outlet Type6 – NEMA 5-15R7 – NEMA 5-15Rdecides which plugs fit without an adapter
Runtime at Full Load3 min3.5 minPR1000LCDRT1U: longer published runtime at full load
Typical Recharge Time8 h6 hPR1000LCDRT1U: ready again sooner after an outage
Surge Suppression (Joules)1150 J1030 JOR1000LCDRM1U: more surge energy absorbed over the unit’s life
Form FactorRackmountRack / Towerdecides where it fits: on a desk, on the floor or in a rack
Physical Weight (lb)30.2 lb35.9 lbmatters for where it sits and how it ships, not for what it can carry

What the choice is not about

Both models publish the same value for these, so they cannot decide it either way.

  • UPS Topology: Line Interactive
  • Input Plug Type: NEMA 5-15P
  • Battery Type: Sealed Lead-Acid Battery

Both records come from this site’s pages for the OR1000LCDRM1U and the PR1000LCDRT1U, where every figure carries its source. Read our methodology.