CyberPower OR1000LCDRM1U vs CyberPower PR1000LCDRT1U uninterruptible power supply (UPS) Line-Interactive 1 kVA 800 W 7 AC outlet(s)
Which one to buy depends on what you plug in and what you pay. Below: the setups one carries and the other cannot, the price per watt, the replacement battery, and every published specification where they differ. No unit was tested here; every figure is from the model’s own page.
Which one to choose
- Choose the OR1000LCDRM1U if price decides: it is about $190 less by our price estimates; or if typical transfer time and surge suppression (joules) matter to you (less time without power when it switches to battery; more surge energy absorbed over the unit’s life).
- Choose the PR1000LCDRT1U if you need to run a small studio: two desks, storage and network (about 613.1 W), which the OR1000LCDRM1U cannot carry; or if output power factor and outlets – total matter to you (more of the rating is usable as real power; more outlets in total).
Setups that separate them
Each setup’s draw is the sum of published figures for its devices, the same totals the model pages use. A unit is roomy at 80% of its watt limit or less, tight above that, and short when the load exceeds the limit.
| Setup | OR1000LCDRM1U | PR1000LCDRT1U |
|---|---|---|
| Two workstations sharing a NAS (up to 525.2 W) | Tight (88% of limit) | Roomy (66% of limit) |
| Small studio: two desks, storage and network (up to 613.1 W) | Cannot carry (102% of limit) | Roomy (77% of limit) |
What it costs to own
| Cost | OR1000LCDRM1U | PR1000LCDRT1U |
|---|---|---|
| Price per watt of capacity | About $0.85 per W | About $0.88 per W |
| Replacement battery | RB0670X4, est. about $70 | RB0690X4B, est. about $130 |
CyberPower
CyberPower OR1000LCDRM1U
- Real power limit
- 600 W
- Rated capacity
- 1000 VA
- Estimated price
- Est. about $510
CyberPower
CyberPower PR1000LCDRT1U uninterruptible power supply (UPS) Line-Interactive 1 kVA 800 W 7 AC outlet(s)
- Real power limit
- 800 W
- Rated capacity
- 1000 VA
- Estimated price
- Est. about $700
Where they differ
| Specification | OR1000LCDRM1U | PR1000LCDRT1U | What the difference means |
|---|---|---|---|
| Watts | 600 W | 800 W | PR1000LCDRT1U: more real-power headroom for the same equipment |
| On Battery Waveform | Simulated Sine Wave | Sine Wave | matters for equipment with active-PFC power supplies, which prefer a sine wave |
| Typical Transfer Time | 8 ms | 10 ms | OR1000LCDRM1U: less time without power when it switches to battery |
| Output Power Factor | 0.6 | 0.8 | PR1000LCDRT1U: more of the rating is usable as real power |
| Outlets – Total | 6 | 7 | PR1000LCDRT1U: more outlets in total |
| Outlets – Battery & Surge Protected | 4 | 6 | PR1000LCDRT1U: more plugs stay powered during an outage |
| Outlet Type | 6 – NEMA 5-15R | 7 – NEMA 5-15R | decides which plugs fit without an adapter |
| Runtime at Full Load | 3 min | 3.5 min | PR1000LCDRT1U: longer published runtime at full load |
| Typical Recharge Time | 8 h | 6 h | PR1000LCDRT1U: ready again sooner after an outage |
| Surge Suppression (Joules) | 1150 J | 1030 J | OR1000LCDRM1U: more surge energy absorbed over the unit’s life |
| Form Factor | Rackmount | Rack / Tower | decides where it fits: on a desk, on the floor or in a rack |
| Physical Weight (lb) | 30.2 lb | 35.9 lb | matters for where it sits and how it ships, not for what it can carry |
What the choice is not about
Both models publish the same value for these, so they cannot decide it either way.
- UPS Topology: Line Interactive
- Input Plug Type: NEMA 5-15P
- Battery Type: Sealed Lead-Acid Battery
Both records come from this site’s pages for the OR1000LCDRM1U and the PR1000LCDRT1U, where every figure carries its source. Read our methodology.