UPS battery backup · US 120V
CyberPower AVRG900U
A full desk of equipment: a computer, its monitors and the network gear that has to stay up with it.
- Capacity
- 900 VA
- Real power limit
- 480 W
- On battery
- Simulated Sine Wave
- Design
- Line Interactive
Estimated price: about $100 Our estimate for a new unit, from listings seen in November 2026. Not a live price.

What to know before buying
Check equipment that requires pure sine wave
Battery output is simulated sine wave. If your equipment requires pure sine wave, choose a UPS with that output instead. Source
Compare new-unit eBay listings
This model has no qualifying listing at the moment. A listing appears here as soon as one does.
We may earn a commission if you buy through these links.
No new unit of this model is listed at a checked price right now. Used and pickup-only listings exist on eBay and are deliberately not shown: every price on this site is a new unit that ships, so a used one has no comparable figure to put beside it. The specifications below are unaffected — they describe the model, not a listing.
What this model actually powers
A limit this size carries a complete desk — desktop, monitors, network — or a living-room setup, with room left over for the storage box beside it.
Each example adds up published power figures for real equipment and compares the total with this model’s 480 W real-power limit as published by the manufacturer. The examples shown are the ones nearest this limit; a bundle far below or far above it would say nothing useful. These are running-load figures, not startup surge, and your own equipment will differ.
Creator workstation, two monitors and a 4-bay NAS
86.2–231.2 W18–48% of this model’s 480 W
about 248.8 W free
Room for one more Mac mini (M4 Pro) idle-to-max (140 W), but not a Mac Studio (M3 Ultra) idle-to-max (270 W).
TV, console and soundbar
247.2–283.2 W52–59% of this model’s 480 W
about 196.8 W free
Room for one more Mac Studio (M4 Max) idle-to-max (145 W), but not a Mac Studio (M3 Ultra) idle-to-max (270 W).
What is in a TV, console and soundbar, and every model measured against it
Home server closet
131.1–294.5 W27–61% of this model’s 480 W
about 185.5 W free
Room for one more Mac Studio (M4 Max) idle-to-max (145 W), but not a Mac Studio (M3 Ultra) idle-to-max (270 W).
High-end workstation with an 8-bay NAS
82.5–377.9 W17–79% of this model’s 480 W
about 102.1 W free
Room for one more 8-port PoE+ switch maximum (90 W), but not a desktop 3D printer (120 W).
Two workstations sharing a NAS
112.2–525.2 W23–109% of this model’s 480 W
more than this model can carry
What is in this example
- Mac Studio (M3 Ultra) idle-to-max power: 9–270 W (source)
- Mac Studio (M4 Max) idle-to-max power: 6–145 W (source)
- 32-inch monitor operating power: 27.8 W (source)
- 27-inch monitor typical and rated power: 20–26 W (source)
- 24-inch monitor typical and rated power: 17–24 W (source)
- 4-bay NAS access power: 32.41 W (source)
A UPS runs longer the less it carries, so a total near the limit buys less time than a light one. Startup draw is not included because it depends on the equipment you connect.
AVRG900U published runtime
Manufacturer reference points, not a runtime guarantee for your setup. Battery age, temperature and equipment load affect results.
Check your equipment load
Start with the watts you know. Add VA from your equipment or meter when available. Each result checks one limit; startup demand and waveform compatibility need separate confirmation.
The W and VA limits used here come from the manufacturer specification.
This model has 6 manufacturer-verified battery-backed outlets. Count plugs connected directly to the UPS. Surge-only outlets do not keep equipment running during an outage. Check adapter spacing in the outlet diagram. View sources
Which outlets stay live
- 6 outlets on battery of 12; the other 6 outlets are surge-only and go dark with the mains. Among the 9 of 15 models tracked here that publish this figure, values run from 3 to 8 with a midpoint of 6. This model's 6 is within 2% of that midpoint, which is too close to call a difference.
- Socket type: NEMA 5-15R — household plugs fit directly. Plug families
What replacing the battery costs
- Replacement cartridge RB1290: about $20That is our estimated price for a new part.
- Over five years, one replacement at the three-to-five-year interval sealed batteries are rated for: about $20, 20% of the unit’s own estimated price (about $100).
- Why the battery is a consumable
How long each example would run
From the published runtime at half load (10 min) and at full load (2 min). Bounds only: the site does not estimate between two measurements it did not take.
- Creator workstation, two monitors and a 4-bay NAS at 48% of the limit: at least 10 min — it is under half load.
- TV, console and soundbar at 59% of the limit: between 2 and 10 min.
- Home server closet at 61% of the limit: between 2 and 10 min.
- High-end workstation with an 8-bay NAS at 79% of the limit: between 2 and 10 min.
Running it from a generator
- Accepts 57–63 Hz (6 Hz wide) — narrow: a generator whose frequency drifts will push it onto battery repeatedly. What transferring means
How much of the rating is usable, and what it rides through
53% of the VA rating is real power
Rated 900 VA and 480 W, a power factor of 0.53. Equipment draws watts, so the 480 W figure is the one to size against; the 900 VA number is the larger of the two and is the one printed on the box.
Rides the wall from 90 V to 148 V
Against a nominal 120 V US supply that is a sag of 25% or a swell of 23% before the unit has to switch to its battery. A wider window means fewer transfers during brownouts, and fewer transfers means less battery wear.
1030 J surge energy rating
The energy the surge suppression is rated to absorb over its life, not per event. Among the 14 of 15 models tracked here that publish this figure, values run from 120 J to 1780 J with a midpoint of 1150 J. This model's 1030 J is below that midpoint.
About 8 hours to recharge
Time to return to a full charge after a deep discharge. Outages that arrive in clusters can catch the battery part-charged, so the second outage of a day may not get the published runtime. Among the 15 of 15 models tracked here that publish this figure, values run from 2 h to 16 h with a midpoint of 8 h. This model's 8 h is within 2% of that midpoint, which is too close to call a difference.
What changes in the same capacity range
Compare the published limits before paying for more capacity. A higher power rating alone does not establish longer runtime.
- VA: 700 VA vs 900 VA
- Watts: 400 W vs 480 W
- On Battery Waveform: Sine Wave vs Simulated Sine Wave
- Outlets – Total: 6 vs 12
Where this model appears next to others
Same figures as above, arranged against a different question.
Full specifications
50 published figures, grouped. The largest groups are open; the rest expand. Each group names where its figures came from.
Power10 figures
- VA
- 900 VA
- Watts
- 480 W
- On Battery Waveform
- Simulated Sine Wave
- UPS Topology
- Line Interactive
- Typical Transfer Time
- 4 ms
- Output Power Factor
- 0.5
- Input Plug Type
- NEMA 5-15P
- Nominal Input Voltage
- 120 V
- Surge Suppression (Joules)
- 1030 J
- Input Frequency Range
- 57 Hz – 63 Hz
Battery10 figures
- Runtime at Half Load
- 10 min
- Runtime at Full Load
- 2 min
- Typical Recharge Time
- 8 h
- Battery Type
- Sealed Lead-Acid Battery
- Battery Size
- 12 V
- Battery Quantity
- 1
- User Replaceable Battery
- Yes
- Replacement Battery Cartridge
- RB1290
- Replacement Battery Cartridge Quantity
- 1
- Battery Capacity
- 9 Ah
Features6 figures
- Automatic voltage regulation (AVR)
- Y
- EMI/RFI noise filtering
- Y
- Highest input voltage it runs on
- 148 V
- Lowest input voltage it runs on
- 90 V
- Power protection features
- Overload
- Surge protection
- Y
icecat — catalogue values, not manufacturer-checked
Operational conditions5 figures
- Non operating altitude
- 0 - 15000 m
- Operating altitude
- 0 - 2000 m
- Operating relative humidity range
- 0 - 95 %
- Operating temperature range
- 0 - 40 °C
- Storage temperature range
- -15 - 45 °C
icecat — catalogue values, not manufacturer-checked
Outlets4 figures
- Outlets – Total
- 12
- Outlets – Battery & Surge Protected
- 6
- Outlet Type
- 12 – NEMA 5-15R
- Outlets – Surge-Only Protected
- 6
Physical4 figures
- Form Factor
- Compact
- Physical Dimensions – (WxHxD) (in)
- 12.2 x 7 x 3.5 in
- Cord Length
- 1.5 m
- Physical Weight (lb)
- 14.04 lb
Weight & dimensions3 figures
- Depth
- 88.8 mm
- Height
- 177.7 mm
- Width
- 309.8 mm
icecat — catalogue values, not manufacturer-checked
Ports & interfaces3 figures
- Modem (RJ-11) ports
- 3
- Power plug
- NEMA 5-15P
- USB 2.0 ports
- 1
icecat — catalogue values, not manufacturer-checked
Certificates1 figure
- Compliance certificates
- RoHS
icecat — catalogue values, not manufacturer-checked
Design1 figure
- Product colour
- Black
icecat — catalogue values, not manufacturer-checked
Safety regulation & standards1 figure
- Safety
- UL1778 4th, cUL 107.3-05, FCC/DoC Class B
icecat — catalogue values, not manufacturer-checked
Sustainability1 figure
- Sustainability certificates
- ENERGY STAR
icecat — catalogue values, not manufacturer-checked
Sources and buying notes
This comparison uses published specifications, not hands-on tests. Prices are listing observations and can change. Read our full methodology.
- CyberPower specification ↗
Checked 2026-10-19 - icecat catalogue record
Checked 2026-10-19
Before you order
- Startup demand: Startup draw depends on the connected equipment.
- Equipment compatibility: Confirm plug, voltage, waveform, and both W and VA limits.
Comparison updated October 19, 2026.