UPS battery backup · US 120V

CyberPower AVRG900U

A full desk of equipment: a computer, its monitors and the network gear that has to stay up with it.

Capacity
900 VA
Real power limit
480 W
On battery
Simulated Sine Wave
Design
Line Interactive
Check current price on eBay ↗

Estimated price: about $100 Our estimate for a new unit, from listings seen in November 2026. Not a live price.

CyberPower AVRG900U uninterruptible power supply (UPS) 0.9 kVA 480 W 12 AC outlet(s) uninterruptible power supply
MPN AVRG900U

What to know before buying

Check equipment that requires pure sine wave

Battery output is simulated sine wave. If your equipment requires pure sine wave, choose a UPS with that output instead. Source

Compare new-unit eBay listings

This model has no qualifying listing at the moment. A listing appears here as soon as one does.

We may earn a commission if you buy through these links.

No new unit of this model is listed at a checked price right now. Used and pickup-only listings exist on eBay and are deliberately not shown: every price on this site is a new unit that ships, so a used one has no comparable figure to put beside it. The specifications below are unaffected — they describe the model, not a listing.

What this model actually powers

A limit this size carries a complete desk — desktop, monitors, network — or a living-room setup, with room left over for the storage box beside it.

Each example adds up published power figures for real equipment and compares the total with this model’s 480 W real-power limit as published by the manufacturer. The examples shown are the ones nearest this limit; a bundle far below or far above it would say nothing useful. These are running-load figures, not startup surge, and your own equipment will differ.

  • Creator workstation, two monitors and a 4-bay NAS

    86.2–231.2 W18–48% of this model’s 480 W

    about 248.8 W free

    Room for one more Mac mini (M4 Pro) idle-to-max (140 W), but not a Mac Studio (M3 Ultra) idle-to-max (270 W).

    What is in this example
    • Mac Studio (M4 Max) idle-to-max power: 6–145 W (source)
    • 32-inch monitor operating power: 27.8 W (source)
    • 27-inch monitor typical and rated power: 20–26 W (source)
    • 4-bay NAS access power: 32.41 W (source)
  • TV, console and soundbar

    247.2–283.2 W52–59% of this model’s 480 W

    about 196.8 W free

    Room for one more Mac Studio (M4 Max) idle-to-max (145 W), but not a Mac Studio (M3 Ultra) idle-to-max (270 W).

    What is in a TV, console and soundbar, and every model measured against it

  • Home server closet

    131.1–294.5 W27–61% of this model’s 480 W

    about 185.5 W free

    Room for one more Mac Studio (M4 Max) idle-to-max (145 W), but not a Mac Studio (M3 Ultra) idle-to-max (270 W).

    What is in this example
    • 8-bay NAS sleep-to-typical power: 25.668–54.067 W (source)
    • 8-port PoE+ switch maximum power: 90 W (source)
    • Mac mini (M4 Pro) idle-to-max power: 5–140 W (source)
    • Wi-Fi router active power: 5.2 W (source)
    • Cable modem active power: 5.2 W (source)
  • High-end workstation with an 8-bay NAS

    82.5–377.9 W17–79% of this model’s 480 W

    about 102.1 W free

    Room for one more 8-port PoE+ switch maximum (90 W), but not a desktop 3D printer (120 W).

    What is in this example
    • Mac Studio (M3 Ultra) idle-to-max power: 9–270 W (source)
    • 32-inch monitor operating power: 27.8 W (source)
    • 27-inch monitor typical and rated power: 20–26 W (source)
    • 8-bay NAS sleep-to-typical power: 25.668–54.067 W (source)
  • Two workstations sharing a NAS

    112.2–525.2 W23–109% of this model’s 480 W

    more than this model can carry

    What is in this example
    • Mac Studio (M3 Ultra) idle-to-max power: 9–270 W (source)
    • Mac Studio (M4 Max) idle-to-max power: 6–145 W (source)
    • 32-inch monitor operating power: 27.8 W (source)
    • 27-inch monitor typical and rated power: 20–26 W (source)
    • 24-inch monitor typical and rated power: 17–24 W (source)
    • 4-bay NAS access power: 32.41 W (source)

A UPS runs longer the less it carries, so a total near the limit buys less time than a light one. Startup draw is not included because it depends on the equipment you connect.

AVRG900U published runtime

Manufacturer reference points, not a runtime guarantee for your setup. Battery age, temperature and equipment load affect results.

10 min50% of rated load
2 min100% of rated load

Where these runtime figures come from

Check your equipment load

Start with the watts you know. Add VA from your equipment or meter when available. Each result checks one limit; startup demand and waveform compatibility need separate confirmation.

The W and VA limits used here come from the manufacturer specification.

This model has 6 manufacturer-verified battery-backed outlets. Count plugs connected directly to the UPS. Surge-only outlets do not keep equipment running during an outage. Check adapter spacing in the outlet diagram. View sources

Which outlets stay live

  • 6 outlets on battery of 12; the other 6 outlets are surge-only and go dark with the mains. Among the 9 of 15 models tracked here that publish this figure, values run from 3 to 8 with a midpoint of 6. This model's 6 is within 2% of that midpoint, which is too close to call a difference.
  • Socket type: NEMA 5-15R — household plugs fit directly. Plug families

What replacing the battery costs

  • Replacement cartridge RB1290: about $20That is our estimated price for a new part.
  • Over five years, one replacement at the three-to-five-year interval sealed batteries are rated for: about $20, 20% of the unit’s own estimated price (about $100).
  • Why the battery is a consumable

How long each example would run

From the published runtime at half load (10 min) and at full load (2 min). Bounds only: the site does not estimate between two measurements it did not take.

  • Creator workstation, two monitors and a 4-bay NAS at 48% of the limit: at least 10 min — it is under half load.
  • TV, console and soundbar at 59% of the limit: between 2 and 10 min.
  • Home server closet at 61% of the limit: between 2 and 10 min.
  • High-end workstation with an 8-bay NAS at 79% of the limit: between 2 and 10 min.

Running it from a generator

  • Accepts 57–63 Hz (6 Hz wide) — narrow: a generator whose frequency drifts will push it onto battery repeatedly. What transferring means

How much of the rating is usable, and what it rides through

53% of the VA rating is real power

Rated 900 VA and 480 W, a power factor of 0.53. Equipment draws watts, so the 480 W figure is the one to size against; the 900 VA number is the larger of the two and is the one printed on the box.

Rides the wall from 90 V to 148 V

Against a nominal 120 V US supply that is a sag of 25% or a swell of 23% before the unit has to switch to its battery. A wider window means fewer transfers during brownouts, and fewer transfers means less battery wear.

1030 J surge energy rating

The energy the surge suppression is rated to absorb over its life, not per event. Among the 14 of 15 models tracked here that publish this figure, values run from 120 J to 1780 J with a midpoint of 1150 J. This model's 1030 J is below that midpoint.

About 8 hours to recharge

Time to return to a full charge after a deep discharge. Outages that arrive in clusters can catch the battery part-charged, so the second outage of a day may not get the published runtime. Among the 15 of 15 models tracked here that publish this figure, values run from 2 h to 16 h with a midpoint of 8 h. This model's 8 h is within 2% of that midpoint, which is too close to call a difference.

What changes in the same capacity range

Compare the published limits before paying for more capacity. A higher power rating alone does not establish longer runtime.

CyberPower PFC Sinewave uninterruptible power supply (UPS) Line-Interactive 0.7 kVA 400 W 6 AC outlet(s)
  • VA: 700 VA vs 900 VA
  • Watts: 400 W vs 480 W
  • On Battery Waveform: Sine Wave vs Simulated Sine Wave
  • Outlets – Total: 6 vs 12

Where this model appears next to others

Same figures as above, arranged against a different question.

Full specifications

50 published figures, grouped. The largest groups are open; the rest expand. Each group names where its figures came from.

Power10 figures
VA
900 VA
Watts
480 W
On Battery Waveform
Simulated Sine Wave
UPS Topology
Line Interactive
Typical Transfer Time
4 ms
Output Power Factor
0.5
Input Plug Type
NEMA 5-15P
Nominal Input Voltage
120 V
Surge Suppression (Joules)
1030 J
Input Frequency Range
57 Hz – 63 Hz

CyberPower specification ↗

Battery10 figures
Runtime at Half Load
10 min
Runtime at Full Load
2 min
Typical Recharge Time
8 h
Battery Type
Sealed Lead-Acid Battery
Battery Size
12 V
Battery Quantity
1
User Replaceable Battery
Yes
Replacement Battery Cartridge
RB1290
Replacement Battery Cartridge Quantity
1
Battery Capacity
9 Ah

CyberPower specification ↗

Features6 figures
Automatic voltage regulation (AVR)
Y
EMI/RFI noise filtering
Y
Highest input voltage it runs on
148 V
Lowest input voltage it runs on
90 V
Power protection features
Overload
Surge protection
Y

icecat — catalogue values, not manufacturer-checked

Operational conditions5 figures
Non operating altitude
0 - 15000 m
Operating altitude
0 - 2000 m
Operating relative humidity range
0 - 95 %
Operating temperature range
0 - 40 °C
Storage temperature range
-15 - 45 °C

icecat — catalogue values, not manufacturer-checked

Outlets4 figures
Outlets – Total
12
Outlets – Battery & Surge Protected
6
Outlet Type
12 – NEMA 5-15R
Outlets – Surge-Only Protected
6

CyberPower specification ↗

Physical4 figures
Form Factor
Compact
Physical Dimensions – (WxHxD) (in)
12.2 x 7 x 3.5 in
Cord Length
1.5 m
Physical Weight (lb)
14.04 lb

CyberPower specification ↗

Weight & dimensions3 figures
Depth
88.8 mm
Height
177.7 mm
Width
309.8 mm

icecat — catalogue values, not manufacturer-checked

Ports & interfaces3 figures
Modem (RJ-11) ports
3
Power plug
NEMA 5-15P
USB 2.0 ports
1

icecat — catalogue values, not manufacturer-checked

Warranty1 figure
Product Warranty
3 Year Limited Warranty

CyberPower specification ↗

Certificates1 figure
Compliance certificates
RoHS

icecat — catalogue values, not manufacturer-checked

Design1 figure
Product colour
Black

icecat — catalogue values, not manufacturer-checked

Safety regulation & standards1 figure
Safety
UL1778 4th, cUL 107.3-05, FCC/DoC Class B

icecat — catalogue values, not manufacturer-checked

Sustainability1 figure
Sustainability certificates
ENERGY STAR

icecat — catalogue values, not manufacturer-checked

Sources and buying notes

This comparison uses published specifications, not hands-on tests. Prices are listing observations and can change. Read our full methodology.

Before you order

  • Startup demand: Startup draw depends on the connected equipment.
  • Equipment compatibility: Confirm plug, voltage, waveform, and both W and VA limits.

Comparison updated October 19, 2026.