UPS battery backup · US 120V

CyberPower CP850PFCLCD

A full desk of equipment: a computer, its monitors and the network gear that has to stay up with it.

Capacity
850 VA
Real power limit
510 W
On battery
Sine Wave
Design
Line Interactive
Check current price on eBay ↗

Estimated price: about $170 Our estimate for a new unit, from listings seen in November 2026. Not a live price.

CyberPower CP850PFCLCD uninterruptible power supply (UPS) Line-Interactive 0.85 kVA 510 W 10 AC outlet(s) uninterruptible power supply
MPN CP850PFCLCD

Compare new-unit eBay listings

This model has no qualifying listing at the moment. A listing appears here as soon as one does.

We may earn a commission if you buy through these links.

No new unit of this model is listed at a checked price right now. Used and pickup-only listings exist on eBay and are deliberately not shown: every price on this site is a new unit that ships, so a used one has no comparable figure to put beside it. The specifications below are unaffected — they describe the model, not a listing.

What this model actually powers

A limit this size carries a complete desk — desktop, monitors, network — or a living-room setup, with room left over for the storage box beside it.

Each example adds up published power figures for real equipment and compares the total with this model’s 510 W real-power limit as published by the manufacturer. The examples shown are the ones nearest this limit; a bundle far below or far above it would say nothing useful. These are running-load figures, not startup surge, and your own equipment will differ.

  • Creator workstation, two monitors and a 4-bay NAS

    86.2–231.2 W17–45% of this model’s 510 W

    about 278.8 W free

    Room for one more Mac Studio (M3 Ultra) idle-to-max (270 W).

    What is in this example
    • Mac Studio (M4 Max) idle-to-max power: 6–145 W (source)
    • 32-inch monitor operating power: 27.8 W (source)
    • 27-inch monitor typical and rated power: 20–26 W (source)
    • 4-bay NAS access power: 32.41 W (source)
  • TV, console and soundbar

    247.2–283.2 W48–56% of this model’s 510 W

    about 226.8 W free

    Room for one more Mac Studio (M4 Max) idle-to-max (145 W), but not a Mac Studio (M3 Ultra) idle-to-max (270 W).

    What is in a TV, console and soundbar, and every model measured against it

  • Home server closet

    131.1–294.5 W26–58% of this model’s 510 W

    about 215.5 W free

    Room for one more Mac Studio (M4 Max) idle-to-max (145 W), but not a Mac Studio (M3 Ultra) idle-to-max (270 W).

    What is in this example
    • 8-bay NAS sleep-to-typical power: 25.668–54.067 W (source)
    • 8-port PoE+ switch maximum power: 90 W (source)
    • Mac mini (M4 Pro) idle-to-max power: 5–140 W (source)
    • Wi-Fi router active power: 5.2 W (source)
    • Cable modem active power: 5.2 W (source)
  • High-end workstation with an 8-bay NAS

    82.5–377.9 W16–74% of this model’s 510 W

    about 132.1 W free

    Room for one more game console (126 W), but not a Mac mini (M4 Pro) idle-to-max (140 W).

    What is in this example
    • Mac Studio (M3 Ultra) idle-to-max power: 9–270 W (source)
    • 32-inch monitor operating power: 27.8 W (source)
    • 27-inch monitor typical and rated power: 20–26 W (source)
    • 8-bay NAS sleep-to-typical power: 25.668–54.067 W (source)
  • Two workstations sharing a NAS

    112.2–525.2 W22–103% of this model’s 510 W

    more than this model can carry

    What is in this example
    • Mac Studio (M3 Ultra) idle-to-max power: 9–270 W (source)
    • Mac Studio (M4 Max) idle-to-max power: 6–145 W (source)
    • 32-inch monitor operating power: 27.8 W (source)
    • 27-inch monitor typical and rated power: 20–26 W (source)
    • 24-inch monitor typical and rated power: 17–24 W (source)
    • 4-bay NAS access power: 32.41 W (source)

A UPS runs longer the less it carries, so a total near the limit buys less time than a light one. Startup draw is not included because it depends on the equipment you connect.

CP850PFCLCD published runtime

Manufacturer reference points, not a runtime guarantee for your setup. Battery age, temperature and equipment load affect results.

9 min50% of rated load
3 min100% of rated load

Where these runtime figures come from

Check your equipment load

Start with the watts you know. Add VA from your equipment or meter when available. Each result checks one limit; startup demand and waveform compatibility need separate confirmation.

The W and VA limits used here come from the manufacturer specification.

This model has 5 manufacturer-verified battery-backed outlets. Count plugs connected directly to the UPS. Surge-only outlets do not keep equipment running during an outage. Check adapter spacing in the outlet diagram. View sources

Which outlets stay live

  • 5 outlets on battery of 10; the other 5 outlets are surge-only and go dark with the mains. Among the 13 of 15 models tracked here that publish this figure, values run from 3 to 9 with a midpoint of 6. This model's 5 is below that midpoint.
  • Socket type: NEMA 5-15R — household plugs fit directly. Plug families

What replacing the battery costs

  • Replacement cartridge RB1280A: about $20That is our estimated price for a new part.
  • Over five years, one replacement at the three-to-five-year interval sealed batteries are rated for: about $20, 12% of the unit’s own estimated price (about $170).
  • Why the battery is a consumable

How long each example would run

From the published runtime at half load (9 min) and at full load (3 min). Bounds only: the site does not estimate between two measurements it did not take.

  • Creator workstation, two monitors and a 4-bay NAS at 45% of the limit: at least 9 min — it is under half load.
  • TV, console and soundbar at 56% of the limit: between 3 and 9 min.
  • Home server closet at 58% of the limit: between 3 and 9 min.
  • High-end workstation with an 8-bay NAS at 74% of the limit: between 3 and 9 min.

How a computer talks to it

  • 1 Ethernet port. Several hosts can shut down from it without a cable to each. USB versus network management
  • Front panel: LCD, with an audible alarm.

Running it from a generator

  • Accepts 57–63 Hz (6 Hz wide) — narrow: a generator whose frequency drifts will push it onto battery repeatedly. What transferring means

What changes in the same capacity range

Compare the published limits before paying for more capacity. A higher power rating alone does not establish longer runtime.

CyberPower Smart App Sinewave uninterruptible power supply (UPS) Line-Interactive 0.75 kVA 750 W 6 AC outlet(s)
  • VA: 750 VA vs 850 VA
  • Watts: 750 W vs 510 W
  • Outlets – Total: 6 vs 10
  • Form Factor: Tower vs Mini-Tower

Where this model appears next to others

Same figures as above, arranged against a different question.

Full specifications

49 published figures, grouped. The largest groups are open; the rest expand. Each group names where its figures came from.

Battery11 figures
Runtime at Half Load
9 min
Runtime at Full Load
3 min
Typical Recharge Time
8 h
Battery Type
Sealed Lead-Acid Battery
Battery Size
12 V
Battery Quantity
1
User Replaceable Battery
Yes
Replacement Battery Cartridge
RB1280A (for serial numbers beginning with CQD) RB1290 (for serial numbers beginning with CX2) RB1290 RB1280A
Replacement Battery Cartridge Quantity
1
Battery Capacity
9 Ah
Hot swap battery
N

CyberPower specification, icecat ↗ — manufacturer-checked and catalogue values, see Sources

Power10 figures
VA
850 VA
Watts
510 W
On Battery Waveform
Sine Wave
UPS Topology
Line Interactive
Typical Transfer Time
4 ms
Output Power Factor
0.6
Input Plug Type
NEMA 5-15P
Nominal Input Voltage
120 V
Input Frequency Range
57 Hz – 63 Hz
Surge Suppression (Joules)
1150 J

CyberPower specification ↗

Features5 figures
Audible alarm
Y
Highest input voltage it runs on
142 V
Lowest input voltage it runs on
78 V
Output operation voltage max
120 V
Output operation voltage min
120 V

icecat — catalogue values, not manufacturer-checked

Outlets4 figures
Outlets – Total
10
Outlets – Battery & Surge Protected
5
Outlets – Surge-Only Protected
5
Outlet Type
10 – NEMA 5-15R

CyberPower specification ↗

Physical4 figures
Form Factor
Mini-Tower
Physical Dimensions – (WxHxD) (in)
3.9 x 9.7 x 10.2 in
Physical Weight (lb)
14.9 lb
Cord Length
1.5 m

CyberPower specification ↗

Other features3 figures
Battery type
12V/8.5AH
Dimensions
3.9 x 10.4 x 9.1 in
Weight
14.9 lb

icecat — catalogue values, not manufacturer-checked

Design3 figures
Display type
LCD
LED indicators
Y
Product colour
Black

icecat — catalogue values, not manufacturer-checked

Ports & interfaces3 figures
Ethernet LAN (RJ-45) ports
1
Modem (RJ-11) ports
1
Serial ports
1

icecat — catalogue values, not manufacturer-checked

Certificates2 figures
Certification
UL1778, cUL 107.3, FCC DOC Class B
Compliance certificates
RoHS

icecat — catalogue values, not manufacturer-checked

Operational conditions2 figures
Operating relative humidity range
0 - 90 %
Operating temperature range
0 - 40 °C

icecat — catalogue values, not manufacturer-checked

Controls1 figure
LCD
Multifunction LCD

CyberPower specification ↗

Warranty1 figure
Product Warranty
3 Year Limited Warranty

CyberPower specification ↗

Sources and buying notes

This comparison uses published specifications, not hands-on tests. Prices are listing observations and can change. Read our full methodology.

Before you order

  • Startup demand: Startup draw depends on the connected equipment.
  • Equipment compatibility: Confirm plug, voltage, waveform, and both W and VA limits.

Comparison updated October 19, 2026.