UPS battery backup · US 120V

CyberPower CPS425SL

A desk-side unit for a modem, a router and one computer — enough to ride out a blink and shut down cleanly.

Capacity
425 VA
Real power limit
230 W
On battery
Simulated Sine Wave
Design
Standby
Check current price on eBay ↗No new unit of this model is listed at a checked price right now. Used and pickup-only listings do exist on eBay, but every price on this site is a new unit that ships, so none of them are shown here. The models at this rating that are currently listed are on the page above.
CyberPower CPS425SL uninterruptible power supply (UPS) Standby (Offline) 0.425 kVA 230 W 6 AC outlet(s) uninterruptible power supply
MPN CPS425SL

What to know before buying

Check equipment that requires pure sine wave

Battery output is simulated sine wave. If your equipment requires pure sine wave, choose a UPS with that output instead. Source

Compare new-unit eBay listings

This model has no qualifying listing at the moment. A listing appears here as soon as one does.

We may earn a commission if you buy through these links.

No new unit of this model is listed at a checked price right now. Used and pickup-only listings exist on eBay and are deliberately not shown: every price on this site is a new unit that ships, so a used one has no comparable figure to put beside it. The specifications below are unaffected — they describe the model, not a listing.

What this model actually powers

A limit this size is for the network and one light desk: modem, router, a small NAS, a compact desktop. A full desktop with two monitors is already most of it.

Each example adds up published power figures for real equipment and compares the total with this model’s 230 W real-power limit as published by the manufacturer. The examples shown are the ones nearest this limit; a bundle far below or far above it would say nothing useful. These are running-load figures, not startup surge, and your own equipment will differ.

  • Home office desk

    88.4–124.4 W38–54% of this model’s 230 W

    about 105.6 W free

    Room for one more 8-port PoE+ switch maximum (90 W), but not a desktop 3D printer (120 W).

    What is in a home office desk, and every model measured against it

  • Desktop 3D printer and its host

    92–132 W40–57% of this model’s 230 W

    about 98 W free

    Room for one more 8-port PoE+ switch maximum (90 W), but not a game console (126 W).

    What is in a desktop 3D printer and its host, and every model measured against it

  • Workstation with a 4-bay NAS

    110.4–146.4 W48–64% of this model’s 230 W

    about 83.6 W free

    Room for one more 55-inch TV (77 W), but not a 8-port PoE+ switch maximum (90 W).

    What is in a workstation with a 4-bay NAS, and every model measured against it

  • Compact pro desktop with two monitors

    58–199 W25–87% of this model’s 230 W

    about 31 W free

    Room for one more mesh Wi-Fi node (25 W), but not a 4-bay NAS (32.41 W).

    What is in this example
    • Mac mini (M4 Pro) idle-to-max power: 5–140 W (source)
    • 32-inch monitor operating power: 27.8 W (source)
    • 27-inch monitor typical and rated power: 20–26 W (source)
    • Wi-Fi router active power: 5.2 W (source)
  • Creator workstation, two monitors and a 4-bay NAS

    86.2–231.2 W37–101% of this model’s 230 W

    more than this model can carry

    What is in this example
    • Mac Studio (M4 Max) idle-to-max power: 6–145 W (source)
    • 32-inch monitor operating power: 27.8 W (source)
    • 27-inch monitor typical and rated power: 20–26 W (source)
    • 4-bay NAS access power: 32.41 W (source)

A UPS runs longer the less it carries, so a total near the limit buys less time than a light one. Startup draw is not included because it depends on the equipment you connect.

CPS425SL published runtime

Manufacturer reference points, not a runtime guarantee for your setup. Battery age, temperature and equipment load affect results.

9 min50% of rated load
2 min100% of rated load

Where these runtime figures come from

Check your equipment load

Start with the watts you know. Add VA from your equipment or meter when available. Each result checks one limit; startup demand and waveform compatibility need separate confirmation.

The W and VA limits used here come from the manufacturer specification.

This model has 3 manufacturer-verified battery-backed outlets. Count plugs connected directly to the UPS. Surge-only outlets do not keep equipment running during an outage. Check adapter spacing in the outlet diagram. View sources

Which outlets stay live

  • 3 outlets on battery of 6; the other 3 outlets are surge-only and go dark with the mains.
  • Socket type: NEMA 5-15R — household plugs fit directly. Plug families
  • 6 are spaced wide, so a power brick fits without covering the socket beside it.

How long each example would run

From the published runtime at half load (9 min) and at full load (2 min). Bounds only: the site does not estimate between two measurements it did not take.

  • Home office desk at 54% of the limit: between 2 and 9 min.
  • Desktop 3D printer and its host at 57% of the limit: between 2 and 9 min.
  • Workstation with a 4-bay NAS at 64% of the limit: between 2 and 9 min.
  • Compact pro desktop with two monitors at 87% of the limit: between 2 and 9 min.

How much energy the battery holds

  • About 48 Wh: one battery at 12 V and 4 Ah. At the rated 230 W that is a ceiling of 12.5 min before inverter losses and the battery’s own limits — the published runtime figures, where the page has them, are the real number.

How it switches to battery

  • Standby — the inverter starts only on failure; an active-PFC supply may reset on the gap. How this design behaves
  • Transfer time: 4 ms — well inside a typical supply’s hold-up time. Hold-up time

Running it from a generator

  • Accepts 57–63 Hz (6 Hz wide) — narrow: a generator whose frequency drifts will push it onto battery repeatedly. What transferring means

Where this model appears next to others

Same figures as above, arranged against a different question.

Full specifications

43 published figures, grouped. The largest groups are open; the rest expand. Each group names where its figures came from.

Power10 figures
VA
425 VA
Watts
230 W
On Battery Waveform
Simulated Sine Wave
UPS Topology
Standby
Typical Transfer Time
4 ms
Input Plug Type
NEMA 5-15P
Surge Suppression (Joules)
585 J
Input Frequency Range
57 Hz – 63 Hz
Input Voltage on Utility
100V to 140V
On-Battery Output Voltage
120Vac ± 5%

CyberPower specification ↗

Battery9 figures
Battery Capacity
4 Ah
Runtime at Half Load
9 min
Runtime at Full Load
2 min
Typical Recharge Time
8 h
Battery Type
Sealed Lead-Acid Battery
Battery Size
12 V
Battery Quantity
1
Replacement Battery Cartridge
BB Battery – BP4-12
Replacement battery cartridge
BB - BP4-12

CyberPower specification, icecat ↗ — manufacturer-checked and catalogue values, see Sources

Outlets5 figures
Outlets – Total
6
Outlets – Battery & Surge Protected
3
Outlets – Surge-Only Protected
3
Outlets – Widely Spaced
6
Outlet Type
6 – NEMA 5-15R

CyberPower specification ↗

Other features5 figures
Dimensions
9.75 x 3.25 x 6.25 in
Dimensions
248 x 83 x 159 mm
Input connection type
NEMA 5-15P
Operating temperature range
32 - 95 °F
Weight
8 lb

icecat — catalogue values, not manufacturer-checked

Physical3 figures
Physical Dimensions – (WxHxD) (in)
9.75 x 6.25 x 3.25 in
Physical Weight (lb)
8 lb
Cord Length
1.8 m

CyberPower specification ↗

Features3 figures
Audible alarm
Y
EMI/RFI noise filtering
Y
Response time
4 ms

icecat — catalogue values, not manufacturer-checked

Design2 figures
Form factor
Compact
Product colour
Black

icecat — catalogue values, not manufacturer-checked

Ports & interfaces2 figures
Modem (RJ-11) ports
3
Serial ports
1

icecat — catalogue values, not manufacturer-checked

Operational conditions2 figures
Operating relative humidity range
0 - 95 %
Operating temperature range
0 - 40 °C

icecat — catalogue values, not manufacturer-checked

Warranty1 figure
Product Warranty
3 Year Limited Warranty

CyberPower specification ↗

Certificates1 figure
Certification
UL1778, cUL, FCC DOC B

icecat — catalogue values, not manufacturer-checked

Sources and buying notes

This comparison uses published specifications, not hands-on tests. Prices are listing observations and can change. Read our full methodology.

Before you order

  • Startup demand: Startup draw depends on the connected equipment.
  • Equipment compatibility: Confirm plug, voltage, waveform, and both W and VA limits.

Comparison updated November 15, 2026.