UPS battery backup · US 120V

CyberPower ST900U

A full desk of equipment: a computer, its monitors and the network gear that has to stay up with it.

Capacity
900 VA
Real power limit
500 W
On battery
Simulated Sine Wave
Design
Standby
Check current price on eBay ↗

Estimated price: about $130 Our estimate for a new unit, from listings seen in November 2026. Not a live price.

CyberPower ST900U uninterruptible power supply (UPS) Standby (Offline) 0.9 kVA 500 W 12 AC outlet(s) uninterruptible power supply
MPN ST900U

What to know before buying

Check equipment that requires pure sine wave

Battery output is simulated sine wave. If your equipment requires pure sine wave, choose a UPS with that output instead. Source

Compare new-unit eBay listings

This model has no qualifying listing at the moment. A listing appears here as soon as one does.

We may earn a commission if you buy through these links.

No new unit of this model is listed at a checked price right now. Used and pickup-only listings exist on eBay and are deliberately not shown: every price on this site is a new unit that ships, so a used one has no comparable figure to put beside it. The specifications below are unaffected — they describe the model, not a listing.

What this model actually powers

A limit this size carries a complete desk — desktop, monitors, network — or a living-room setup, with room left over for the storage box beside it.

Each example adds up published power figures for real equipment and compares the total with this model’s 500 W real-power limit as published by the manufacturer. The examples shown are the ones nearest this limit; a bundle far below or far above it would say nothing useful. These are running-load figures, not startup surge, and your own equipment will differ.

  • Creator workstation, two monitors and a 4-bay NAS

    86.2–231.2 W17–46% of this model’s 500 W

    about 268.8 W free

    Room for one more Mac mini (M4 Pro) idle-to-max (140 W), but not a Mac Studio (M3 Ultra) idle-to-max (270 W).

    What is in this example
    • Mac Studio (M4 Max) idle-to-max power: 6–145 W (source)
    • 32-inch monitor operating power: 27.8 W (source)
    • 27-inch monitor typical and rated power: 20–26 W (source)
    • 4-bay NAS access power: 32.41 W (source)
  • TV, console and soundbar

    247.2–283.2 W49–57% of this model’s 500 W

    about 216.8 W free

    Room for one more Mac Studio (M4 Max) idle-to-max (145 W), but not a Mac Studio (M3 Ultra) idle-to-max (270 W).

    What is in a TV, console and soundbar, and every model measured against it

  • Home server closet

    131.1–294.5 W26–59% of this model’s 500 W

    about 205.5 W free

    Room for one more Mac Studio (M4 Max) idle-to-max (145 W), but not a Mac Studio (M3 Ultra) idle-to-max (270 W).

    What is in this example
    • 8-bay NAS sleep-to-typical power: 25.668–54.067 W (source)
    • 8-port PoE+ switch maximum power: 90 W (source)
    • Mac mini (M4 Pro) idle-to-max power: 5–140 W (source)
    • Wi-Fi router active power: 5.2 W (source)
    • Cable modem active power: 5.2 W (source)
  • High-end workstation with an 8-bay NAS

    82.5–377.9 W17–76% of this model’s 500 W

    about 122.1 W free

    Room for one more desktop 3D printer (120 W), but not a game console (126 W).

    What is in this example
    • Mac Studio (M3 Ultra) idle-to-max power: 9–270 W (source)
    • 32-inch monitor operating power: 27.8 W (source)
    • 27-inch monitor typical and rated power: 20–26 W (source)
    • 8-bay NAS sleep-to-typical power: 25.668–54.067 W (source)
  • Two workstations sharing a NAS

    112.2–525.2 W22–105% of this model’s 500 W

    more than this model can carry

    What is in this example
    • Mac Studio (M3 Ultra) idle-to-max power: 9–270 W (source)
    • Mac Studio (M4 Max) idle-to-max power: 6–145 W (source)
    • 32-inch monitor operating power: 27.8 W (source)
    • 27-inch monitor typical and rated power: 20–26 W (source)
    • 24-inch monitor typical and rated power: 17–24 W (source)
    • 4-bay NAS access power: 32.41 W (source)

A UPS runs longer the less it carries, so a total near the limit buys less time than a light one. Startup draw is not included because it depends on the equipment you connect.

ST900U published runtime

Manufacturer reference points, not a runtime guarantee for your setup. Battery age, temperature and equipment load affect results.

7.5 min50% of rated load
2 min100% of rated load

Where these runtime figures come from

Check your equipment load

Start with the watts you know. Add VA from your equipment or meter when available. Each result checks one limit; startup demand and waveform compatibility need separate confirmation.

The W and VA limits used here come from the manufacturer specification.

This model has 6 manufacturer-verified battery-backed outlets. Count plugs connected directly to the UPS. Surge-only outlets do not keep equipment running during an outage. Check adapter spacing in the outlet diagram. View sources

Which outlets stay live

  • 6 outlets on battery of 12; the other 6 outlets are surge-only and go dark with the mains. Among the 11 of 14 models tracked here that publish this figure, values run from 4 to 10 with a midpoint of 8. This model's 6 is below that midpoint.
  • Socket type: NEMA 5-15R — household plugs fit directly. Plug families
  • 4 are spaced wide, so a power brick fits without covering the socket beside it.

How long each example would run

From the published runtime at half load (7.5 min) and at full load (2 min). Bounds only: the site does not estimate between two measurements it did not take.

  • Creator workstation, two monitors and a 4-bay NAS at 46% of the limit: at least 7.5 min — it is under half load.
  • TV, console and soundbar at 57% of the limit: between 2 and 7.5 min.
  • Home server closet at 59% of the limit: between 2 and 7.5 min.
  • High-end workstation with an 8-bay NAS at 76% of the limit: between 2 and 7.5 min.

How it switches to battery

  • Standby — the inverter starts only on failure; an active-PFC supply may reset on the gap. How this design behaves
  • Transfer time: 8 ms — inside most supplies’ hold-up time, with less margin under heavy load. Among the 13 of 14 models tracked here that publish this figure, values run from 0 ms to 8 ms with a midpoint of 4 ms. This model's 8 ms sits at the high end: none of the models tracked here publishes a higher figure. Hold-up time

Running it from a generator

  • Accepts 47–63 Hz (16 Hz wide) — wide enough to ride a portable generator’s frequency wander without dropping to battery. What transferring means

How much of the rating is usable, and what it rides through

56% of the VA rating is real power

Rated 900 VA and 500 W, a power factor of 0.56. Equipment draws watts, so the 500 W figure is the one to size against; the 900 VA number is the larger of the two and is the one printed on the box.

Rides the wall from 96 V to 140 V

Against a nominal 120 V US supply that is a sag of 20% or a swell of 17% before the unit has to switch to its battery. A wider window means fewer transfers during brownouts, and fewer transfers means less battery wear.

890 J surge energy rating

The energy the surge suppression is rated to absorb over its life, not per event. Among the 14 of 14 models tracked here that publish this figure, values run from 320 J to 2430 J with a midpoint of 960 J. This model's 890 J is below that midpoint.

About 8 hours to recharge

Time to return to a full charge after a deep discharge. Outages that arrive in clusters can catch the battery part-charged, so the second outage of a day may not get the published runtime. Among the 14 of 14 models tracked here that publish this figure, values run from 3 h to 24 h with a midpoint of 8 h. This model's 8 h is within 2% of that midpoint, which is too close to call a difference.

What changes in the same capacity range

Compare the published limits before paying for more capacity. A higher power rating alone does not establish longer runtime.

CyberPower AVRG750U uninterruptible power supply (UPS) 0.75 kVA 450 W 12 AC outlet(s)
  • VA: 750 VA vs 900 VA
  • Watts: 450 W vs 500 W
  • UPS Topology: Line Interactive vs Standby

Where this model appears next to others

Same figures as above, arranged against a different question.

Full specifications

59 published figures, grouped. The largest groups are open; the rest expand. Each group names where its figures came from.

Features11 figures
Audible alarm modes
Alarm when on battery,Fault,Low battery alarm,Overload alarm
Audible alarm
Y
Highest input voltage it runs on
140 V
Lowest input voltage it runs on
96 V
Output frequency
50/60 Hz
Output operation voltage max
120 V
Output operation voltage min
120 V
Power protection features
Overload
Socket circuit breaker
Y
Surge protection
Y
Transfer time line mode to battery mode
8 ms

icecat — catalogue values, not manufacturer-checked

Power10 figures
VA
900 VA
Watts
500 W
UPS Topology
Standby
Typical Transfer Time
8 ms
Output Power Factor
0.6
Input Plug Type
NEMA 5-15P
Nominal Input Voltage
120 V
Surge Suppression (Joules)
890 J
On Battery Waveform
Simulated Sine Wave
Input Frequency Range
47 Hz – 63 Hz

CyberPower specification ↗

Battery9 figures
Runtime at Half Load
7.5 min
Runtime at Full Load
2 min
Typical Recharge Time
8 h
Battery Type
Sealed Lead-Acid Battery
Battery Size
12 V
Battery Quantity
1
User Replaceable Battery
No
Field-serviceable Battery
Replaceable by qualified technician
Battery Capacity
7.2 Ah

CyberPower specification ↗

Outlets5 figures
Outlets – Total
12
Outlets – Battery & Surge Protected
6
Outlets – Surge-Only Protected
6
Outlets – Widely Spaced
4
Outlet Type
12 – NEMA 5-15R

CyberPower specification ↗

Operational conditions5 figures
Non operating altitude
0 - 15000 m
Operating altitude
0 - 3000 m
Operating relative humidity range
0 - 95 %
Operating temperature range
0 - 40 °C
Storage temperature range
-15 - 45 °C

icecat — catalogue values, not manufacturer-checked

Physical4 figures
Form Factor
Compact
Physical Dimensions – (WxHxD) (in)
12.2 x 3.1 x 7 in
Physical Weight (lb)
7.7 lb
Cord Length
1.5 m

CyberPower specification ↗

Ports & interfaces4 figures
Power plug
NEMA 5-15P
USB 2.0 ports
2
USB port
Y
USB port type
USB Type-A

icecat — catalogue values, not manufacturer-checked

Weight & dimensions3 figures
Depth
177 mm
Height
78 mm
Width
309 mm

icecat — catalogue values, not manufacturer-checked

Packaging content2 figures
Cables included
USB cable
Manual
Y

icecat — catalogue values, not manufacturer-checked

Design2 figures
LED indicators
Power
Product colour
Black

icecat — catalogue values, not manufacturer-checked

Warranty1 figure
Product Warranty
3 Year Limited Warranty

CyberPower specification ↗

Certificates1 figure
Compliance certificates
RoHS

icecat — catalogue values, not manufacturer-checked

Safety regulation & standards1 figure
Safety
UL1778, cUL, FCC DOC B, CEC

icecat — catalogue values, not manufacturer-checked

Sustainability1 figure
Sustainability certificates
ENERGY STAR

icecat — catalogue values, not manufacturer-checked

Sources and buying notes

This comparison uses published specifications, not hands-on tests. Prices are listing observations and can change. Read our full methodology.

Before you order

  • Startup demand: Startup draw depends on the connected equipment.
  • Equipment compatibility: Confirm plug, voltage, waveform, and both W and VA limits.

Comparison updated October 19, 2026.