CyberPower ST900U
A full desk of equipment: a computer, its monitors and the network gear that has to stay up with it.
- Capacity
- 900 VA
- Real power limit
- 500 W
- On battery
- Simulated Sine Wave
- Design
- Standby
Estimated price: about $130 Our estimate for a new unit, from listings seen in November 2026. Not a live price.

What to know before buying
Check equipment that requires pure sine wave
Battery output is simulated sine wave. If your equipment requires pure sine wave, choose a UPS with that output instead. Source
Compare new-unit eBay listings
This model has no qualifying listing at the moment. A listing appears here as soon as one does.
We may earn a commission if you buy through these links.
No new unit of this model is listed at a checked price right now. Used and pickup-only listings exist on eBay and are deliberately not shown: every price on this site is a new unit that ships, so a used one has no comparable figure to put beside it. The specifications below are unaffected — they describe the model, not a listing.
What this model actually powers
A limit this size carries a complete desk — desktop, monitors, network — or a living-room setup, with room left over for the storage box beside it.
Each example adds up published power figures for real equipment and compares the total with this model’s 500 W real-power limit as published by the manufacturer. The examples shown are the ones nearest this limit; a bundle far below or far above it would say nothing useful. These are running-load figures, not startup surge, and your own equipment will differ.
Creator workstation, two monitors and a 4-bay NAS
86.2–231.2 W17–46% of this model’s 500 W
about 268.8 W free
Room for one more Mac mini (M4 Pro) idle-to-max (140 W), but not a Mac Studio (M3 Ultra) idle-to-max (270 W).
TV, console and soundbar
247.2–283.2 W49–57% of this model’s 500 W
about 216.8 W free
Room for one more Mac Studio (M4 Max) idle-to-max (145 W), but not a Mac Studio (M3 Ultra) idle-to-max (270 W).
What is in a TV, console and soundbar, and every model measured against it
Home server closet
131.1–294.5 W26–59% of this model’s 500 W
about 205.5 W free
Room for one more Mac Studio (M4 Max) idle-to-max (145 W), but not a Mac Studio (M3 Ultra) idle-to-max (270 W).
High-end workstation with an 8-bay NAS
82.5–377.9 W17–76% of this model’s 500 W
about 122.1 W free
Room for one more desktop 3D printer (120 W), but not a game console (126 W).
Two workstations sharing a NAS
112.2–525.2 W22–105% of this model’s 500 W
more than this model can carry
What is in this example
- Mac Studio (M3 Ultra) idle-to-max power: 9–270 W (source)
- Mac Studio (M4 Max) idle-to-max power: 6–145 W (source)
- 32-inch monitor operating power: 27.8 W (source)
- 27-inch monitor typical and rated power: 20–26 W (source)
- 24-inch monitor typical and rated power: 17–24 W (source)
- 4-bay NAS access power: 32.41 W (source)
A UPS runs longer the less it carries, so a total near the limit buys less time than a light one. Startup draw is not included because it depends on the equipment you connect.
ST900U published runtime
Manufacturer reference points, not a runtime guarantee for your setup. Battery age, temperature and equipment load affect results.
Check your equipment load
Start with the watts you know. Add VA from your equipment or meter when available. Each result checks one limit; startup demand and waveform compatibility need separate confirmation.
The W and VA limits used here come from the manufacturer specification.
This model has 6 manufacturer-verified battery-backed outlets. Count plugs connected directly to the UPS. Surge-only outlets do not keep equipment running during an outage. Check adapter spacing in the outlet diagram. View sources
Which outlets stay live
- 6 outlets on battery of 12; the other 6 outlets are surge-only and go dark with the mains. Among the 11 of 14 models tracked here that publish this figure, values run from 4 to 10 with a midpoint of 8. This model's 6 is below that midpoint.
- Socket type: NEMA 5-15R — household plugs fit directly. Plug families
- 4 are spaced wide, so a power brick fits without covering the socket beside it.
How long each example would run
From the published runtime at half load (7.5 min) and at full load (2 min). Bounds only: the site does not estimate between two measurements it did not take.
- Creator workstation, two monitors and a 4-bay NAS at 46% of the limit: at least 7.5 min — it is under half load.
- TV, console and soundbar at 57% of the limit: between 2 and 7.5 min.
- Home server closet at 59% of the limit: between 2 and 7.5 min.
- High-end workstation with an 8-bay NAS at 76% of the limit: between 2 and 7.5 min.
How it switches to battery
- Standby — the inverter starts only on failure; an active-PFC supply may reset on the gap. How this design behaves
- Transfer time: 8 ms — inside most supplies’ hold-up time, with less margin under heavy load. Among the 13 of 14 models tracked here that publish this figure, values run from 0 ms to 8 ms with a midpoint of 4 ms. This model's 8 ms sits at the high end: none of the models tracked here publishes a higher figure. Hold-up time
Running it from a generator
- Accepts 47–63 Hz (16 Hz wide) — wide enough to ride a portable generator’s frequency wander without dropping to battery. What transferring means
How much of the rating is usable, and what it rides through
56% of the VA rating is real power
Rated 900 VA and 500 W, a power factor of 0.56. Equipment draws watts, so the 500 W figure is the one to size against; the 900 VA number is the larger of the two and is the one printed on the box.
Rides the wall from 96 V to 140 V
Against a nominal 120 V US supply that is a sag of 20% or a swell of 17% before the unit has to switch to its battery. A wider window means fewer transfers during brownouts, and fewer transfers means less battery wear.
890 J surge energy rating
The energy the surge suppression is rated to absorb over its life, not per event. Among the 14 of 14 models tracked here that publish this figure, values run from 320 J to 2430 J with a midpoint of 960 J. This model's 890 J is below that midpoint.
About 8 hours to recharge
Time to return to a full charge after a deep discharge. Outages that arrive in clusters can catch the battery part-charged, so the second outage of a day may not get the published runtime. Among the 14 of 14 models tracked here that publish this figure, values run from 3 h to 24 h with a midpoint of 8 h. This model's 8 h is within 2% of that midpoint, which is too close to call a difference.
What changes in the same capacity range
Compare the published limits before paying for more capacity. A higher power rating alone does not establish longer runtime.
- VA: 750 VA vs 900 VA
- Watts: 450 W vs 500 W
- UPS Topology: Line Interactive vs Standby
Where this model appears next to others
Same figures as above, arranged against a different question.
Full specifications
59 published figures, grouped. The largest groups are open; the rest expand. Each group names where its figures came from.
Features11 figures
- Audible alarm modes
- Alarm when on battery,Fault,Low battery alarm,Overload alarm
- Audible alarm
- Y
- Highest input voltage it runs on
- 140 V
- Lowest input voltage it runs on
- 96 V
- Output frequency
- 50/60 Hz
- Output operation voltage max
- 120 V
- Output operation voltage min
- 120 V
- Power protection features
- Overload
- Socket circuit breaker
- Y
- Surge protection
- Y
- Transfer time line mode to battery mode
- 8 ms
icecat — catalogue values, not manufacturer-checked
Power10 figures
- VA
- 900 VA
- Watts
- 500 W
- UPS Topology
- Standby
- Typical Transfer Time
- 8 ms
- Output Power Factor
- 0.6
- Input Plug Type
- NEMA 5-15P
- Nominal Input Voltage
- 120 V
- Surge Suppression (Joules)
- 890 J
- On Battery Waveform
- Simulated Sine Wave
- Input Frequency Range
- 47 Hz – 63 Hz
Battery9 figures
- Runtime at Half Load
- 7.5 min
- Runtime at Full Load
- 2 min
- Typical Recharge Time
- 8 h
- Battery Type
- Sealed Lead-Acid Battery
- Battery Size
- 12 V
- Battery Quantity
- 1
- User Replaceable Battery
- No
- Field-serviceable Battery
- Replaceable by qualified technician
- Battery Capacity
- 7.2 Ah
Outlets5 figures
- Outlets – Total
- 12
- Outlets – Battery & Surge Protected
- 6
- Outlets – Surge-Only Protected
- 6
- Outlets – Widely Spaced
- 4
- Outlet Type
- 12 – NEMA 5-15R
Operational conditions5 figures
- Non operating altitude
- 0 - 15000 m
- Operating altitude
- 0 - 3000 m
- Operating relative humidity range
- 0 - 95 %
- Operating temperature range
- 0 - 40 °C
- Storage temperature range
- -15 - 45 °C
icecat — catalogue values, not manufacturer-checked
Physical4 figures
- Form Factor
- Compact
- Physical Dimensions – (WxHxD) (in)
- 12.2 x 3.1 x 7 in
- Physical Weight (lb)
- 7.7 lb
- Cord Length
- 1.5 m
Ports & interfaces4 figures
- Power plug
- NEMA 5-15P
- USB 2.0 ports
- 2
- USB port
- Y
- USB port type
- USB Type-A
icecat — catalogue values, not manufacturer-checked
Weight & dimensions3 figures
- Depth
- 177 mm
- Height
- 78 mm
- Width
- 309 mm
icecat — catalogue values, not manufacturer-checked
Packaging content2 figures
- Cables included
- USB cable
- Manual
- Y
icecat — catalogue values, not manufacturer-checked
Design2 figures
- LED indicators
- Power
- Product colour
- Black
icecat — catalogue values, not manufacturer-checked
Certificates1 figure
- Compliance certificates
- RoHS
icecat — catalogue values, not manufacturer-checked
Safety regulation & standards1 figure
- Safety
- UL1778, cUL, FCC DOC B, CEC
icecat — catalogue values, not manufacturer-checked
Sustainability1 figure
- Sustainability certificates
- ENERGY STAR
icecat — catalogue values, not manufacturer-checked
Sources and buying notes
This comparison uses published specifications, not hands-on tests. Prices are listing observations and can change. Read our full methodology.
- CyberPower specification ↗
Checked 2026-10-19 - icecat catalogue record
Checked 2026-10-19
Before you order
- Startup demand: Startup draw depends on the connected equipment.
- Equipment compatibility: Confirm plug, voltage, waveform, and both W and VA limits.
Comparison updated October 19, 2026.