UPS battery backup · US 120V
Vertiv PSA6E-1000LVT
A full desk of equipment: a computer, its monitors and the network gear that has to stay up with it.
- Capacity
- 1000 VA
- Real power limit
- 550 W
- On battery
- Simulated sine wave
- Design
- Line-interactive
Estimated price: about $180 Our estimate for a new unit, from listings seen in November 2026. Not a live price.

What to know before buying
6 outlets in total, but not all keep power
This record gives the total outlet count and does not say how many are battery-backed rather than surge-only. Most units of this size split the two, so count the plugs you need to keep running and check the manufacturer's outlet diagram before buying. Source
Compare new-unit eBay listings
This model has no qualifying listing at the moment. A listing appears here as soon as one does.
We may earn a commission if you buy through these links.
No new unit of this model is listed at a checked price right now. Used and pickup-only listings exist on eBay and are deliberately not shown: every price on this site is a new unit that ships, so a used one has no comparable figure to put beside it. The specifications below are unaffected — they describe the model, not a listing.
What this model actually powers
A limit this size carries a complete desk — desktop, monitors, network — or a living-room setup, with room left over for the storage box beside it.
Each example adds up published power figures for real equipment and compares the total with this model’s 550 W real-power limit as published by the manufacturer. The examples shown are the ones nearest this limit; a bundle far below or far above it would say nothing useful. These are running-load figures, not startup surge, and your own equipment will differ.
TV, console and soundbar
247.2–283.2 W45–51% of this model’s 550 W
about 266.8 W free
Room for one more Mac Studio (M4 Max) idle-to-max (145 W), but not a Mac Studio (M3 Ultra) idle-to-max (270 W).
What is in a TV, console and soundbar, and every model measured against it
Home server closet
131.1–294.5 W24–54% of this model’s 550 W
about 255.5 W free
Room for one more Mac Studio (M4 Max) idle-to-max (145 W), but not a Mac Studio (M3 Ultra) idle-to-max (270 W).
High-end workstation with an 8-bay NAS
82.5–377.9 W15–69% of this model’s 550 W
about 172.1 W free
Room for one more Mac Studio (M4 Max) idle-to-max (145 W).
Two workstations sharing a NAS
112.2–525.2 W20–95% of this model’s 550 W
about 24.8 W free
Room for one more 2-bay NAS (15 W), but not a mesh Wi-Fi node (25 W).
What is in this example
- Mac Studio (M3 Ultra) idle-to-max power: 9–270 W (source)
- Mac Studio (M4 Max) idle-to-max power: 6–145 W (source)
- 32-inch monitor operating power: 27.8 W (source)
- 27-inch monitor typical and rated power: 20–26 W (source)
- 24-inch monitor typical and rated power: 17–24 W (source)
- 4-bay NAS access power: 32.41 W (source)
Small studio: two desks, storage and network
182.7–613.1 W33–111% of this model’s 550 W
more than this model can carry
What is in this example
- Mac Studio (M3 Ultra) idle-to-max power: 9–270 W (source)
- Mac mini (M4 Pro) idle-to-max power: 5–140 W (source)
- 32-inch monitor operating power: 27.8 W (source)
- 27-inch monitor typical and rated power: 20–26 W (source)
- 8-bay NAS sleep-to-typical power: 25.668–54.067 W (source)
- 8-port PoE+ switch maximum power: 90 W (source)
- Wi-Fi router active power: 5.2 W (source)
A UPS runs longer the less it carries, so a total near the limit buys less time than a light one. Startup draw is not included because it depends on the equipment you connect.
PSA6E-1000LVT published runtime
Manufacturer reference points, not a runtime guarantee for your setup. Battery age, temperature and equipment load affect results.
Check your equipment load
Start with the watts you know. Add VA from your equipment or meter when available. Each result checks one limit; startup demand and waveform compatibility need separate confirmation.
The W and VA limits used here come from the manufacturer specification.
Confirm the battery-backed outlet count in the manufacturer diagram. Count plugs connected directly to the UPS. Surge-only outlets do not keep equipment running during an outage. Check adapter spacing in the outlet diagram. View sources
Which outlets stay live
- 6 outlets in total; how many are battery-backed is not published for this model, so count the plugs that must keep running and check the outlet diagram. Among the 11 of 11 models tracked here that publish this figure, values run from 4 to 10 with a midpoint of 8. This model's 6 is below that midpoint.
Its runtime against a real outage
EIA’s 2024 utility reports give each state’s average interruption length on an ordinary day (major storms excluded). The runtime below is the published half load figure.
- 8 min at half load against a national average interruption of 118.4 min — 7% of it, and a customer sees about 1 such interruption a year.
- A shutdown window, not a ride-through. Even the state with the shortest everyday interruptions (RI, 79.9 min) averages 10× this runtime; the longest (WV) averages 212.6 min. What 8 minutes buys is saving work and shutting down cleanly — which is what a desk unit is for.
- With major storm days included the average interruption runs to hours in most states.
- EIA-861 2024 reliability data · How to read these figures
How long each example would run
From the published runtime at half load (8 min) and at full load (1.8 min). Bounds only: the site does not estimate between two measurements it did not take.
- TV, console and soundbar at 51% of the limit: between 1.8 and 8 min.
- Home server closet at 54% of the limit: between 1.8 and 8 min.
- High-end workstation with an 8-bay NAS at 69% of the limit: between 1.8 and 8 min.
- Two workstations sharing a NAS at 95% of the limit: between 1.8 and 8 min.
Noise, temperature and certifications
- 40 dB — audible in a quiet room, fine in an office. Among the 11 of 11 models tracked here that publish this figure, values run from 40 dB to 45 dB with a midpoint of 40 dB. This model's 40 dB sits at the low end: none of the models tracked here publishes a lower figure. Reading noise figures
- Operating temperature 0 - 40 °C. Batteries age fastest at the top of that range.
- Certifications: CB, CE, EN/IEC 62040-1, UKCA, RCM, EACEN/IEC 62040-2, EN/IEC 61000-3-2, EN 61000-3-3, CAT: C1IEC 61000-4-5ISTA Procedure 3A.
How much of the rating is usable, and what it rides through
55% of the VA rating is real power
Rated 1000 VA and 550 W, a power factor of 0.55. Equipment draws watts, so the 550 W figure is the one to size against; the 1000 VA number is the larger of the two and is the one printed on the box.
Rides the wall from 81 V to 147 V
Against a nominal 120 V US supply that is a sag of 33% or a swell of 23% before the unit has to switch to its battery. A wider window means fewer transfers during brownouts, and fewer transfers means less battery wear.
400 J surge energy rating
The energy the surge suppression is rated to absorb over its life, not per event. Among the 9 of 11 models tracked here that publish this figure, values run from 316 J to 1372 J with a midpoint of 1200 J. This model's 400 J is below that midpoint.
What changes in the same capacity range
Compare the published limits before paying for more capacity. A higher power rating alone does not establish longer runtime.
- Watts: 625 W vs 550 W
- On Battery Waveform: Simulated Sine wave vs Simulated sine wave
- AC outlets: 8 vs 6
- VA: 1100 VA vs 1000 VA
- Watts: 990 W vs 550 W
- On Battery Waveform: Pure Sinewave vs Simulated sine wave
- Real power limit: 900 W vs 550 W
- On Battery Waveform: Pure Sinewave vs Simulated sine wave
- AC outlets: 5 vs 6
Full specifications
44 published figures, grouped. The largest groups are open; the rest expand. Each group names where its figures came from.
Features12 figures
- Efficiency
- 98 %
- EMI/RFI noise filtering
- Y
- Input frequency
- 50/60 Hz
- Highest input voltage it runs on
- 147 V
- Lowest input voltage it runs on
- 81 V
- Noise level
- 40 dB
- Output frequency
- 50/60 Hz
- Output operation voltage max
- 132 V
- Output operation voltage min
- 95 V
- Power protection features
- Overload,Over current,Short circuit,Overcharge
- Surge energy rating
- 400 J
- Surge protection
- Y
icecat — catalogue values, not manufacturer-checked
Operational conditions6 figures
- Non operating altitude
- 0 - 10000 m
- Operating altitude
- 0 - 10000 m
- Operating relative humidity range
- 0 - 95 %
- Operating temperature range
- 0 - 40 °C
- Storage relative humidity range
- 0 - 95 %
- Storage temperature range
- -20 - 40 °C
icecat — catalogue values, not manufacturer-checked
Power5 figures
- VA
- 1000 VA
- Watts
- 550 W
- On Battery Waveform
- Simulated sine wave
- UPS Topology
- Line-interactive
- Nominal Input Voltage
- 120 V
Battery4 figures
- Runtime at Half Load
- 8 min
- Runtime at Full Load
- 1.8 min
- Battery technology
- Sealed Lead Acid (VRLA)
- Battery voltage
- 120 V
Vertiv specification, icecat ↗ — manufacturer-checked and catalogue values, see Sources
Design4 figures
- Cable length
- 1.8 m
- Control type
- Buttons
- LED indicators
- Y
- Product colour
- Black
icecat — catalogue values, not manufacturer-checked
Packaging data4 figures
- Package depth
- 495 mm
- Package height
- 305 mm
- Package weight
- 8500 g
- Package width
- 235 mm
icecat — catalogue values, not manufacturer-checked
Ports & interfaces3 figures
- AC outlets
- 6
- Power plug
- NEMA 5-15P
- USB 2.0 ports
- 1
icecat — catalogue values, not manufacturer-checked
Weight & dimensions3 figures
- Depth
- 355 mm
- Height
- 180 mm
- Width
- 120 mm
icecat — catalogue values, not manufacturer-checked
Certificates2 figures
- Certification
- CB, CE, EN/IEC 62040-1, UKCA, RCM, EACEN/IEC 62040-2, EN/IEC 61000-3-2, EN 61000-3-3, CAT: C1IEC 61000-4-5ISTA Procedure 3A
- Compliance certificates
- REACH,RoHS,WEEE
icecat — catalogue values, not manufacturer-checked
Sources and buying notes
This comparison uses published specifications, not hands-on tests. Prices are listing observations and can change. Read our full methodology.
- Vertiv specification ↗
Checked 2026-10-19 - icecat catalogue record
Checked 2026-10-19
Before you order
- Startup demand: Startup draw depends on the connected equipment.
- Equipment compatibility: Confirm plug, voltage, waveform, and both W and VA limits.
Comparison updated October 19, 2026.