UPS battery backup · US 120V

APC BX850M

A full desk of equipment: a computer, its monitors and the network gear that has to stay up with it.

Capacity
850 VA
Real power limit
510 W
On battery
Stepped approximation to a sinewave
Design
Line Interactive
Check current price on eBay ↗

Estimated price: about $150 Our estimate for a new unit, from listings seen in November 2026. Not a live price.

APC BX850M uninterruptible power supply (UPS) Line-Interactive 0.85 kVA 510 W 8 AC outlet(s) uninterruptible power supply
MPN BX850M

Compare new-unit eBay listings

This model has no qualifying listing at the moment. A listing appears here as soon as one does.

We may earn a commission if you buy through these links.

No new unit of this model is listed at a checked price right now. Used and pickup-only listings exist on eBay and are deliberately not shown: every price on this site is a new unit that ships, so a used one has no comparable figure to put beside it. The specifications below are unaffected — they describe the model, not a listing.

What this model actually powers

A limit this size carries a complete desk — desktop, monitors, network — or a living-room setup, with room left over for the storage box beside it.

Each example adds up published power figures for real equipment and compares the total with this model’s 510 W real-power limit as published by the manufacturer. The examples shown are the ones nearest this limit; a bundle far below or far above it would say nothing useful. These are running-load figures, not startup surge, and your own equipment will differ.

  • Creator workstation, two monitors and a 4-bay NAS

    86.2–231.2 W17–45% of this model’s 510 W

    about 278.8 W free

    Room for one more Mac Studio (M3 Ultra) idle-to-max (270 W).

    What is in this example
    • Mac Studio (M4 Max) idle-to-max power: 6–145 W (source)
    • 32-inch monitor operating power: 27.8 W (source)
    • 27-inch monitor typical and rated power: 20–26 W (source)
    • 4-bay NAS access power: 32.41 W (source)
  • TV, console and soundbar

    247.2–283.2 W48–56% of this model’s 510 W

    about 226.8 W free

    Room for one more Mac Studio (M4 Max) idle-to-max (145 W), but not a Mac Studio (M3 Ultra) idle-to-max (270 W).

    What is in a TV, console and soundbar, and every model measured against it

  • Home server closet

    131.1–294.5 W26–58% of this model’s 510 W

    about 215.5 W free

    Room for one more Mac Studio (M4 Max) idle-to-max (145 W), but not a Mac Studio (M3 Ultra) idle-to-max (270 W).

    What is in this example
    • 8-bay NAS sleep-to-typical power: 25.668–54.067 W (source)
    • 8-port PoE+ switch maximum power: 90 W (source)
    • Mac mini (M4 Pro) idle-to-max power: 5–140 W (source)
    • Wi-Fi router active power: 5.2 W (source)
    • Cable modem active power: 5.2 W (source)
  • High-end workstation with an 8-bay NAS

    82.5–377.9 W16–74% of this model’s 510 W

    about 132.1 W free

    Room for one more game console (126 W), but not a Mac mini (M4 Pro) idle-to-max (140 W).

    What is in this example
    • Mac Studio (M3 Ultra) idle-to-max power: 9–270 W (source)
    • 32-inch monitor operating power: 27.8 W (source)
    • 27-inch monitor typical and rated power: 20–26 W (source)
    • 8-bay NAS sleep-to-typical power: 25.668–54.067 W (source)
  • Two workstations sharing a NAS

    112.2–525.2 W22–103% of this model’s 510 W

    more than this model can carry

    What is in this example
    • Mac Studio (M3 Ultra) idle-to-max power: 9–270 W (source)
    • Mac Studio (M4 Max) idle-to-max power: 6–145 W (source)
    • 32-inch monitor operating power: 27.8 W (source)
    • 27-inch monitor typical and rated power: 20–26 W (source)
    • 24-inch monitor typical and rated power: 17–24 W (source)
    • 4-bay NAS access power: 32.41 W (source)

A UPS runs longer the less it carries, so a total near the limit buys less time than a light one. Startup draw is not included because it depends on the equipment you connect.

BX850M published runtime

Manufacturer reference points, not a runtime guarantee for your setup. Battery age, temperature and equipment load affect results.

8.9 min50% of rated load
2 min100% of rated load

Where these runtime figures come from

Check your equipment load

Start with the watts you know. Add VA from your equipment or meter when available. Each result checks one limit; startup demand and waveform compatibility need separate confirmation.

The W and VA limits used here come from the manufacturer specification.

This model has 4 manufacturer-verified battery-backed outlets. Count plugs connected directly to the UPS. Surge-only outlets do not keep equipment running during an outage. Check adapter spacing in the outlet diagram. View sources

Which outlets stay live

  • 4 outlets on battery of 8; the other 4 outlets are surge-only and go dark with the mains. Among the 6 of 15 models tracked here that publish this figure, values run from 4 to 8 with a midpoint of 4. This model's 4 sits at the low end: none of the models tracked here publishes a lower figure.
  • Socket type: 4 NEMA 5-15R, 4 NEMA 5-15R surge — household plugs fit directly. Plug families

What replacing the battery costs

  • Replacement cartridge replacement battery: about $20That is our estimated price for a new part.
  • Over five years, one replacement at the rated 5-year life: about $20, 13% of the unit’s own estimated price (about $150).
  • Why the battery is a consumable

How long each example would run

From the manufacturer’s runtime curve at half load (8.9 min) and at full load (2 min). The curve is the manufacturer’s estimate for new, fully charged batteries, and reads somewhat above the figures datasheets print where both exist. Bounds only.

  • Creator workstation, two monitors and a 4-bay NAS at 45% of the limit: at least 8.9 min — it is under half load.
  • TV, console and soundbar at 56% of the limit: between 2 and 8.9 min.
  • Home server closet at 58% of the limit: between 2 and 8.9 min.
  • High-end workstation with an 8-bay NAS at 74% of the limit: between 2 and 8.9 min.

How a computer talks to it

Running it from a generator

  • Accepts 57–63 Hz (6 Hz wide) — narrow: a generator whose frequency drifts will push it onto battery repeatedly. What transferring means

What changes in the same capacity range

Compare the published limits before paying for more capacity. A higher power rating alone does not establish longer runtime.

CyberPower OR700LCDRM1U uninterruptible power supply (UPS) 0.7 kVA 400 W
  • VA: 700 VA vs 850 VA
  • Watts: 400 W vs 510 W
  • On Battery Waveform: Simulated Sine Wave vs Stepped approximation to a sinewave
  • Outlets – Total: 6 vs 8
CyberPower AVRG750LCD uninterruptible power supply (UPS) Line-Interactive 0.75 kVA 450 W 12 AC outlet(s)
  • VA: 750 VA vs 850 VA
  • Watts: 450 W vs 510 W
  • On Battery Waveform: Simulated Sine Wave vs Stepped approximation to a sinewave
  • Outlets – Total: 12 vs 8

Where this model appears next to others

Same figures as above, arranged against a different question.

Full specifications

46 published figures, grouped. The largest groups are open; the rest expand. Each group names where its figures came from.

Power9 figures
VA
850 VA
Watts
510 W
On Battery Waveform
Stepped approximation to a sinewave
UPS Topology
Line Interactive
Typical Transfer Time
8 ms
Input Plug Type
NEMA 5-15P
Nominal Input Voltage
120 V
Surge Suppression (Joules)
1103 J
Input Frequency Range
57–63 Hz

APC specification ↗

Battery6 figures
Typical Recharge Time
12 h
Replacement Battery Cartridge
RBC17
Runtime at Half Load
8.9 min
Runtime at Full Load
2 min
Battery life max
5 year(s)
Battery technology
Sealed Lead Acid (VRLA)

APC specification, APC runtime curve (estimate), icecat ↗ — manufacturer-checked and catalogue values, see Sources

Features5 figures
Highest input voltage it runs on
139 V
Lowest input voltage it runs on
88 V
Maximum current
12 A
Output frequency regulation
60 Hz
Output operation voltage max
120 V

icecat — catalogue values, not manufacturer-checked

Outlets4 figures
Outlet Type
4 NEMA 5-15R, 4 NEMA 5-15R surge
Outlets – Total
8
Outlets – Battery & Surge Protected
4
Outlets – Surge-Only Protected
4

APC specification ↗

Operational conditions4 figures
Operating relative humidity range
0 - 95 %
Operating temperature range
0 - 40 °C
Storage relative humidity range
0 - 95 %
Storage temperature range
-15 - 45 °C

icecat — catalogue values, not manufacturer-checked

Packaging data4 figures
Package depth
442 mm
Package height
253 mm
Package weight
7600 g
Package width
142 mm

icecat — catalogue values, not manufacturer-checked

Weight & dimensions3 figures
Depth
310 mm
Height
190 mm
Width
91 mm

icecat — catalogue values, not manufacturer-checked

Design3 figures
Display type
LCD
Form factor
Tower
Product colour
Black

icecat — catalogue values, not manufacturer-checked

Physical2 figures
Cord Length
1.8 m
Physical Weight (lb)
15.0 lb

APC specification ↗

Ports & interfaces2 figures
Cabling technology
10/100/1000Base-T(X)
Ethernet LAN (RJ-45) ports
1

icecat — catalogue values, not manufacturer-checked

Certificates2 figures
Certification
California (CEC) Battery Charger, FCC Part 15 Class B, UL 1778
Compliance certificates
RoHS

icecat — catalogue values, not manufacturer-checked

Environment1 figure
Audible Noise
45 dB

APC specification ↗

Sustainability1 figure
Sustainability certificates
ENERGY STAR

icecat — catalogue values, not manufacturer-checked

Sources and buying notes

This comparison uses published specifications, not hands-on tests. Prices are listing observations and can change. Read our full methodology.

Before you order

  • Startup demand: Startup draw depends on the connected equipment.
  • Equipment compatibility: Confirm plug, voltage, waveform, and both W and VA limits.

Comparison updated October 19, 2026.