UPS battery backup · US 120V

APC BX850M uninterruptible power supply (UPS) Line-Interactive 0.85 kVA 510 W 8 AC outlet(s) vs CyberPower CP850AVRLCD

Which one to buy depends on what you plug in and what you pay. Below: the setups one carries and the other cannot, the price per watt, the replacement battery, and every published specification where they differ. No unit was tested here; every figure is from the model’s own page.

Which one to choose

  • Choose the BX850M if surge suppression (joules) matter to you (more surge energy absorbed over the unit’s life).
  • Choose the CP850AVRLCD if typical transfer time and outlets – total matter to you (less time without power when it switches to battery; more outlets in total).

What it costs to own

CostBX850MCP850AVRLCD
Price per watt of capacityAbout $0.29 per WNo estimate
Replacement batteryreplacement battery, est. about $20RB1290

APC

APC BX850M uninterruptible power supply (UPS) Line-Interactive 0.85 kVA 510 W 8 AC outlet(s)

Real power limit
510 W
Rated capacity
850 VA
Estimated price
Est. about $150
Full specs and prices →

CyberPower

CyberPower CP850AVRLCD

Real power limit
510 W
Rated capacity
850 VA
Estimated price
Check current price
Full specs and prices →

Where they differ

SpecificationBX850MCP850AVRLCDWhat the difference means
On Battery WaveformStepped approximation to a sinewaveSimulated Sine Wavematters for equipment with active-PFC power supplies, which prefer a sine wave
Typical Transfer Time8 ms4 msCP850AVRLCD: less time without power when it switches to battery
Outlets – Total89CP850AVRLCD: more outlets in total
Outlets – Battery & Surge Protected45CP850AVRLCD: more plugs stay powered during an outage
Outlet Type4 NEMA 5-15R, 4 NEMA 5-15R surge9 – NEMA 5-15Rdecides which plugs fit without an adapter
Runtime at Half Load8.9 min11 minCP850AVRLCD: longer published runtime at the same share of its rating
Runtime at Full Load2 min3 minCP850AVRLCD: longer published runtime at full load
Typical Recharge Time12 h8 hCP850AVRLCD: ready again sooner after an outage
Surge Suppression (Joules)1103 J1080 JBX850M: more surge energy absorbed over the unit’s life
Form factorTowerMini-Towerdecides where it fits: on a desk, on the floor or in a rack
Physical Weight (lb)15.0 lb15 lbmatters for where it sits and how it ships, not for what it can carry

What the choice is not about

Both models publish the same value for these, so they cannot decide it either way.

  • UPS Topology: Line Interactive
  • Input Plug Type: NEMA 5-15P

Neither of these? every 850VA model is on one page, with the same figures and an estimated price for each.

Both records come from this site’s pages for the BX850M and the CP850AVRLCD, where every figure carries its source. Read our methodology.