UPS battery backup · US 120V
CyberPower CP1000PFCLCD vs CyberPower M1100XL uninterruptible power supply (UPS) Line-Interactive 1.1 kVA 880 W 6 AC outlet(s)
Which one to buy depends on what you plug in and what you pay. Below: the setups one carries and the other cannot, the price per watt, the replacement battery, and every published specification where they differ. No unit was tested here; every figure is from the model’s own page.
Which one to choose
- Choose the CP1000PFCLCD if price decides: it is about $590 less by our price estimates; or if typical transfer time and outlets – total matter to you (less time without power when it switches to battery; more outlets in total).
- Choose the M1100XL if you need to run a small studio: two desks, storage and network (about 613.1 W), which the CP1000PFCLCD cannot carry; or if output power factor and outlets – battery & surge protected matter to you (more of the rating is usable as real power; more plugs stay powered during an outage).
Setups that separate them
Each setup’s draw is the sum of published figures for its devices, the same totals the model pages use. A unit is roomy at 80% of its watt limit or less, tight above that, and short when the load exceeds the limit.
| Setup | CP1000PFCLCD | M1100XL |
|---|---|---|
| Two workstations sharing a NAS (up to 525.2 W) | Tight (88% of limit) | Roomy (60% of limit) |
| Small studio: two desks, storage and network (up to 613.1 W) | Cannot carry (102% of limit) | Roomy (70% of limit) |
What it costs to own
| Cost | CP1000PFCLCD | M1100XL |
|---|---|---|
| Price per watt of capacity | About $0.32 per W | About $0.89 per W |
| Replacement battery | RB1290 | RB1290X3B, est. about $90 |
CyberPower
CyberPower CP1000PFCLCD
- Real power limit
- 600 W
- Rated capacity
- 1000 VA
- Estimated price
- Est. about $190
CyberPower
CyberPower M1100XL uninterruptible power supply (UPS) Line-Interactive 1.1 kVA 880 W 6 AC outlet(s)
- Real power limit
- 880 W
- Rated capacity
- 1100 VA
- Estimated price
- Est. about $780
Where they differ
| Specification | CP1000PFCLCD | M1100XL | What the difference means |
|---|---|---|---|
| Watts | 600 W | 880 W | M1100XL: more real-power headroom for the same equipment |
| VA | 1000 VA | 1100 VA | M1100XL: a higher rating, though watts is the figure to size against |
| On Battery Waveform | Sine Wave | Simulated Sine Wave | matters for equipment with active-PFC power supplies, which prefer a sine wave |
| Typical Transfer Time | 4 ms | 10 ms | CP1000PFCLCD: less time without power when it switches to battery |
| Output Power Factor | 0.6 | 0.8 | M1100XL: more of the rating is usable as real power |
| Outlets – Total | 10 | 6 | CP1000PFCLCD: more outlets in total |
| Outlets – Battery & Surge Protected | 5 | 6 | M1100XL: more plugs stay powered during an outage |
| Outlet Type | 10 – NEMA 5-15R | 6 – 5-15R-HG | decides which plugs fit without an adapter |
| Runtime at Half Load | 6 min | 25 min | M1100XL: longer published runtime at the same share of its rating |
| Runtime at Full Load | 2 min | 10 min | M1100XL: longer published runtime at full load |
| Surge Suppression (Joules) | 1150 J | 1445 J | M1100XL: more surge energy absorbed over the unit’s life |
| Physical Weight (lb) | 15.39 lb | 54 lb | matters for where it sits and how it ships, not for what it can carry |
What the choice is not about
Both models publish the same value for these, so they cannot decide it either way.
- UPS Topology: Line Interactive
- Battery Type: Sealed Lead-Acid Battery
- Form Factor: Mini-Tower
Both records come from this site’s pages for the CP1000PFCLCD and the M1100XL, where every figure carries its source. Read our methodology.