UPS battery backup · US 120V
CyberPower M1100XL
A full desk of equipment: a computer, its monitors and the network gear that has to stay up with it.
- Capacity
- 1100 VA
- Real power limit
- 880 W
- On battery
- Simulated Sine Wave
- Design
- Line Interactive
Estimated price: about $780 Our estimate for a new unit, from listings seen in November 2026. Not a live price.

What to know before buying
Check equipment that requires pure sine wave
Battery output is simulated sine wave. If your equipment requires pure sine wave, choose a UPS with that output instead. Source
Compare new-unit eBay listings
This model has no qualifying listing at the moment. A listing appears here as soon as one does.
We may earn a commission if you buy through these links.
No new unit of this model is listed at a checked price right now. Used and pickup-only listings exist on eBay and are deliberately not shown: every price on this site is a new unit that ships, so a used one has no comparable figure to put beside it. The specifications below are unaffected — they describe the model, not a listing.
What this model actually powers
A limit this size carries a complete desk — desktop, monitors, network — or a living-room setup, with room left over for the storage box beside it.
Each example adds up published power figures for real equipment and compares the total with this model’s 880 W real-power limit as published by the manufacturer. The examples shown are the ones nearest this limit; a bundle far below or far above it would say nothing useful. These are running-load figures, not startup surge, and your own equipment will differ.
TV, console and soundbar
247.2–283.2 W28–32% of this model’s 880 W
about 596.8 W free
Room for 2 more loads the size of a Mac Studio (M3 Ultra) idle-to-max (270 W each).
What is in a TV, console and soundbar, and every model measured against it
Home server closet
131.1–294.5 W15–33% of this model’s 880 W
about 585.5 W free
Room for 2 more loads the size of a Mac Studio (M3 Ultra) idle-to-max (270 W each).
High-end workstation with an 8-bay NAS
82.5–377.9 W9–43% of this model’s 880 W
about 502.1 W free
Room for 3 more loads the size of a Mac Studio (M4 Max) idle-to-max (145 W each).
Two workstations sharing a NAS
112.2–525.2 W13–60% of this model’s 880 W
about 354.8 W free
Room for 2 more loads the size of a Mac mini (M4 Pro) idle-to-max (140 W each).
What is in this example
- Mac Studio (M3 Ultra) idle-to-max power: 9–270 W (source)
- Mac Studio (M4 Max) idle-to-max power: 6–145 W (source)
- 32-inch monitor operating power: 27.8 W (source)
- 27-inch monitor typical and rated power: 20–26 W (source)
- 24-inch monitor typical and rated power: 17–24 W (source)
- 4-bay NAS access power: 32.41 W (source)
Small studio: two desks, storage and network
182.7–613.1 W21–70% of this model’s 880 W
about 266.9 W free
Room for one more Mac Studio (M4 Max) idle-to-max (145 W).
What is in this example
- Mac Studio (M3 Ultra) idle-to-max power: 9–270 W (source)
- Mac mini (M4 Pro) idle-to-max power: 5–140 W (source)
- 32-inch monitor operating power: 27.8 W (source)
- 27-inch monitor typical and rated power: 20–26 W (source)
- 8-bay NAS sleep-to-typical power: 25.668–54.067 W (source)
- 8-port PoE+ switch maximum power: 90 W (source)
- Wi-Fi router active power: 5.2 W (source)
A UPS runs longer the less it carries, so a total near the limit buys less time than a light one. Startup draw is not included because it depends on the equipment you connect.
M1100XL published runtime
Manufacturer reference points, not a runtime guarantee for your setup. Battery age, temperature and equipment load affect results.
Check your equipment load
Start with the watts you know. Add VA from your equipment or meter when available. Each result checks one limit; startup demand and waveform compatibility need separate confirmation.
The W and VA limits used here come from the manufacturer specification.
This model has 6 manufacturer-verified battery-backed outlets. Count plugs connected directly to the UPS. Surge-only outlets do not keep equipment running during an outage. Check adapter spacing in the outlet diagram. View sources
Which outlets stay live
- 6 outlets on battery of 6; every outlet is battery-backed. Among the 9 of 15 models tracked here that publish this figure, values run from 3 to 8 with a midpoint of 6. This model's 6 is within 2% of that midpoint, which is too close to call a difference.
- Socket type: 5-15R-HG — household plugs fit directly. Plug families
What replacing the battery costs
- Replacement cartridge RB1290X3B: about $90That is our estimated price for a new part.
- Over five years, one replacement at the three-to-five-year interval sealed batteries are rated for: about $90, 12% of the unit’s own estimated price (about $780).
- Why the battery is a consumable
How long each example would run
From the published runtime at half load (25 min) and at full load (10 min). Bounds only: the site does not estimate between two measurements it did not take.
- TV, console and soundbar at 32% of the limit: at least 25 min — it is under half load.
- Home server closet at 33% of the limit: at least 25 min — it is under half load.
- High-end workstation with an 8-bay NAS at 43% of the limit: at least 25 min — it is under half load.
- Two workstations sharing a NAS at 60% of the limit: between 10 and 25 min.
- Small studio: two desks, storage and network at 70% of the limit: between 10 and 25 min.
The battery and what replacing it involves
- Sealed Lead-Acid Battery (sealed lead-acid — fades over three to five years regardless of use): 3 batteries, 12 V, 9 Ah. Why chemistry sets the interval
- Recharge: about 8 h to full. Among the 15 of 15 models tracked here that publish this figure, values run from 2 h to 16 h with a midpoint of 8 h. This model's 8 h is within 2% of that midpoint, which is too close to call a difference.
- Hot-swappable: changed under load, no scheduled shutdown. Replacement arrangements
Running it from a generator
- Accepts 57–63 Hz (6 Hz wide) — narrow: a generator whose frequency drifts will push it onto battery repeatedly. What transferring means
What changes in the same capacity range
Compare the published limits before paying for more capacity. A higher power rating alone does not establish longer runtime.
- VA: 1000 VA vs 1100 VA
- Watts: 670 W vs 880 W
- On Battery Waveform: Sine wave vs Simulated Sine Wave
- Form factor: Rackmount vs Mini-Tower
Where this model appears next to others
Same figures as above, arranged against a different question.
Full specifications
64 published figures, grouped. The largest groups are open; the rest expand. Each group names where its figures came from.
Features13 figures
- Audible alarm modes
- Alarm when on battery,Fault,Low battery alarm,Overload alarm
- Audible alarm
- Y
- Automatic voltage regulation (AVR)
- Y
- EMI/RFI noise filtering
- Y
- Highest input voltage it runs on
- 150 V
- Lowest input voltage it runs on
- 88 V
- Maximum current
- 10 A
- Output frequency
- 60 Hz
- Output operation voltage max
- 120 V
- Output operation voltage min
- 120 V
- Power protection features
- Overload
- Socket circuit breaker
- Y
- Transfer time line mode to battery mode
- 10 ms
icecat — catalogue values, not manufacturer-checked
Battery11 figures
- Runtime at Half Load
- 25 min
- Runtime at Full Load
- 10 min
- Typical Recharge Time
- 8 h
- Battery Type
- Sealed Lead-Acid Battery
- Battery Size
- 12 V
- Battery Quantity
- 3
- User Replaceable Battery
- Yes
- Replacement Battery Cartridge Quantity
- 1
- Battery Capacity
- 9 Ah
- Replacement Battery Cartridge
- RB1290X3B
- Hot swap battery
- Y
CyberPower specification, icecat ↗ — manufacturer-checked and catalogue values, see Sources
Power10 figures
- VA
- 1100 VA
- Watts
- 880 W
- On Battery Waveform
- Simulated Sine Wave
- UPS Topology
- Line Interactive
- Typical Transfer Time
- 10 ms
- Output Power Factor
- 0.8
- Input Plug Type
- NEMA 5-15P-HG
- Nominal Input Voltage
- 120 V
- Surge Suppression (Joules)
- 1445 J
- Input Frequency Range
- 57 Hz – 63 Hz
Ports & interfaces7 figures
- Power plug
- NEMA 5-15P-HG
- RS-232 ports
- 1
- Serial interface
- Y
- Serial interface type
- RS-232
- USB 2.0 ports
- 1
- USB port
- Y
- USB port type
- USB Type-B
icecat — catalogue values, not manufacturer-checked
Physical4 figures
- Physical Dimensions – (WxHxD) (in)
- 6.7 x 8.7 x 17 in
- Physical Weight (lb)
- 54 lb
- Cord Length
- 1.8 m
- Form Factor
- Mini-Tower
Operational conditions4 figures
- Operating altitude
- 0 - 3000 m
- Operating relative humidity range
- 0 - 95 %
- Operating temperature range
- 0 - 40 °C
- Storage temperature range
- -15 - 45 °C
icecat — catalogue values, not manufacturer-checked
Outlets3 figures
- Outlets – Total
- 6
- Outlets – Battery & Surge Protected
- 6
- Outlet Type
- 6 – 5-15R-HG
Weight & dimensions3 figures
- Depth
- 431 mm
- Height
- 170 mm
- Width
- 220 mm
icecat — catalogue values, not manufacturer-checked
Design3 figures
- Display type
- LCD
- LED indicators
- Power
- Product colour
- White
icecat — catalogue values, not manufacturer-checked
Packaging content2 figures
- Cables included
- Serial,USB cable
- Manual
- Y
icecat — catalogue values, not manufacturer-checked
Certificates1 figure
- Compliance certificates
- RoHS
icecat — catalogue values, not manufacturer-checked
Safety regulation & standards1 figure
- Safety
- UL1778, CSA, FCC 15 A (EMI), UL60601-1
icecat — catalogue values, not manufacturer-checked
Sources and buying notes
This comparison uses published specifications, not hands-on tests. Prices are listing observations and can change. Read our full methodology.
- CyberPower specification ↗
Checked 2026-10-19 - icecat catalogue record
Checked 2026-10-19
Before you order
- Startup demand: Startup draw depends on the connected equipment.
- Equipment compatibility: Confirm plug, voltage, waveform, and both W and VA limits.
Comparison updated October 19, 2026.